2015
DOI: 10.1016/j.ejrad.2015.05.007
|View full text |Cite
|
Sign up to set email alerts
|

Focal masses in a non-cirrhotic liver: The additional benefit of CEUS over baseline imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
18
0
6

Year Published

2015
2015
2019
2019

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 28 publications
(24 citation statements)
references
References 61 publications
0
18
0
6
Order By: Relevance
“…The widespread use of imaging techniques, such as ultrasound (US), computed-tomography (CT) and magnetic resonance imaging (MRI) has led to a constantly increasing detection and diagnosis of FLLs in completely asymptomatic patients [1][2][3][4]. The frequency of incidentally detected FLLs varies in the literature between 7.2% and 33% for CT, 10.2% and 34.5% for MRI, and between 2.3% and 6.2% for screening US [5].…”
Section: Introductionmentioning
confidence: 99%
“…The widespread use of imaging techniques, such as ultrasound (US), computed-tomography (CT) and magnetic resonance imaging (MRI) has led to a constantly increasing detection and diagnosis of FLLs in completely asymptomatic patients [1][2][3][4]. The frequency of incidentally detected FLLs varies in the literature between 7.2% and 33% for CT, 10.2% and 34.5% for MRI, and between 2.3% and 6.2% for screening US [5].…”
Section: Introductionmentioning
confidence: 99%
“…According to the EFSUMB guideline, CEUS allows the characterization of most of FLLs by analysing the enhancement pattern during the arterial, portal venous and late phases [2,4,5,13]. Previous studies have shown that transabdominal CEUS with low frequency convex transducer is significantly better than unenhanced BMUS for the detection [1,3] and classification [7,10,33] of FLLs. For unclear small FLLs which could not be characterized with confidence by using transabdominal BMUS or Doppler ultrasound techniques, real-time CEUS has demonstrated the ability to characterize them reliably [1,12,21].…”
Section: Discussionmentioning
confidence: 99%
“…Detection of small FLLs of less than 5 mm always is challenging as these lesions often appear isoechoic on B mode ultrasound (BMUS); the same is true for superficial FLLs close to the liver capsule [6]. Over the last decade, with the wide clinical application of microbubble ultrasound contrast agents, contrastenhanced ultrasound (CEUS) has noticeably improved the identification and characterization of FLLs, especially for FLLs less than 10 mm in size [7][8][9][10][11][12]. However, it still proves to be difficult to differentiate malignant and benign FLLs, especially when the lesion is smaller than 10 mm or located superficially [2,13].…”
Section: Introductionmentioning
confidence: 99%
“…컴퓨터를 활용한 영상처리 기술이 발전하면서 이를 이용 하여 초음파 진단의 성능을 개선하고자 하는 연구가 최근 들어 다양하게 시도되고 있다 [1,2]. 예컨대 영상에서 조영증 간 병변 진단의 위한 4가지 유형의 픽셀분류 영상에 적용하 는 에너지 함수는 Equation (7)과 같이 정의된다.…”
Section: 서 론1 )unclassified