2012
DOI: 10.1016/j.arth.2011.08.015
|View full text |Cite
|
Sign up to set email alerts
|

Follow-Up of a Modular Rotating Hinge Knee System in Salvage Revision Total Knee Arthroplasty

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

1
16
0

Year Published

2012
2012
2024
2024

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 39 publications
(17 citation statements)
references
References 28 publications
1
16
0
Order By: Relevance
“… 8 Hinge type contrite implants with rotating components are a good option for TKA revision where there is significative bone loss and ligament instability. 12 - 15 , 20 , 21 Sanguineti et al, 12 with 20 cases of TKA revision surgeries using the Endo-Model rotating-hinge prosthesis (Waldemar Link GmbH and Co., Hamburg, Germany), Neumann et al 22 , with 24 cases using the NexGen Rotating Hinge Knee (Zimmer Biomet Inc., Warsaw, IN, USA) and Bistolfi et al 14 with 50 cases also using the Endo-Model prosthesis, are some of the largest series showing the follow-up of patients submitted to TKA revision with this type of implant. These implants, however, although also of the hinge type, have a quite different design than the implants used in this study.…”
Section: Discussionmentioning
confidence: 99%
“… 8 Hinge type contrite implants with rotating components are a good option for TKA revision where there is significative bone loss and ligament instability. 12 - 15 , 20 , 21 Sanguineti et al, 12 with 20 cases of TKA revision surgeries using the Endo-Model rotating-hinge prosthesis (Waldemar Link GmbH and Co., Hamburg, Germany), Neumann et al 22 , with 24 cases using the NexGen Rotating Hinge Knee (Zimmer Biomet Inc., Warsaw, IN, USA) and Bistolfi et al 14 with 50 cases also using the Endo-Model prosthesis, are some of the largest series showing the follow-up of patients submitted to TKA revision with this type of implant. These implants, however, although also of the hinge type, have a quite different design than the implants used in this study.…”
Section: Discussionmentioning
confidence: 99%
“…Initially, a high rate of failure was described with rotatinghinge knee implants, whereas some good results have been described more recently. 1,5,[13][14][15][16] Nevertheless, several authors report discouraging results, 2,17,18 and many think that the hinge transfers high stresses to the implant-bone interface and causes loosening.…”
Section: Discussionmentioning
confidence: 99%
“…Although the complication rate was high, it was similar to rates reported in the literature for this type of revision surgery. 4,16,19 Deficit of the external popliteal sciatic nerve is not a frequent complication in knee arthroplasty but can occur in revision surgery. The authors preferred a wide cementation because the cement is easy to handle, can fill almost any kind of defect, is stable when polymerized, and gives excellent metaepiphyseal fixation.…”
Section: Discussionmentioning
confidence: 99%
“…9,10 Survivorship will also be reduced due to the increased stress placed at the implant-bone interface, secondary to the less normal kinematics of the joint and resulting increased forces generated. 11 Even the scores for clinical results seem to be worse than in conventional non-constrained replacement of the knee.…”
Section: Introductionmentioning
confidence: 99%