2013
DOI: 10.1016/j.ajodo.2012.11.020
|View full text |Cite
|
Sign up to set email alerts
|

Force levels in complex tooth alignment with conventional and self-ligating brackets

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
24
1
4

Year Published

2014
2014
2023
2023

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 33 publications
(31 citation statements)
references
References 34 publications
2
24
1
4
Order By: Relevance
“…The rounded arch slot walls of Synergy brackets, which were used in our study, reduce BI and FR, which is important for efficient management of sliding between the archwire and bracket during the levelling phase (22). In this study, when the elastomeric ligation was tied onto the inner tie wings of the Synergy brackets, free movement of the archwire in the bracket slot was enabled (passive ligation design) (2,(15)(16)(17); consequently, frictional force was reduced. However, at high vertical displacements, such as 3 mm, the Synergy brackets had higher F/O force ratios.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The rounded arch slot walls of Synergy brackets, which were used in our study, reduce BI and FR, which is important for efficient management of sliding between the archwire and bracket during the levelling phase (22). In this study, when the elastomeric ligation was tied onto the inner tie wings of the Synergy brackets, free movement of the archwire in the bracket slot was enabled (passive ligation design) (2,(15)(16)(17); consequently, frictional force was reduced. However, at high vertical displacements, such as 3 mm, the Synergy brackets had higher F/O force ratios.…”
Section: Discussionmentioning
confidence: 99%
“…When the elastomeric ligation is tied on the inner tie wings of the brackets, the bosses prevent the ligation from contacting the archwire. Synergy brackets have a passive ligation design (i.e., no ligation force is exerted on the archwire) (2,(15)(16)(17).…”
Section: Methodsmentioning
confidence: 99%
“…Os bráquetes ativos testados mostraram resistência com valores variando de 12 a 54 cN e os passivos igual a zero ou inexistente 17 . Montasser et al 18 , em 2013, recomendou os arcos de 0,012" termoativados para a fase de alinhamento inicial. 18 Em 2015, este mesmo grupo de autores 19 , em outro estudo, avaliou o diâmetro do fio e concluiu que aumentando-se a secção transversal do fio, eleva-se os níveis de força, para os AL e BC, invariavelmente 19 .…”
Section: Magnitude De Forçaunclassified
“…The following factors are thought to affect the force magnitude at each tooth: the ligation method used for the archwire [6][7][8][9][10][11][12] ; the diameter of the archwire 13) ; and the inter-bracket distance 7) .…”
Section: Introductionmentioning
confidence: 99%
“…Recently, force magnitudes of nickel-titanium alloy archwires with different ligation methods have been compared using a modified three-point bending test. Brackets were bonded to a metal block [6][7][8] or resin formed model 9,13) and the force from the ligated and deflected nickel-titanium alloy archwires were measured at a single point. Significant differences in the force magnitude from the archwire were found when using a stainless steel ligature, elastic module, and the self-ligating method [6][7][8]13) .…”
Section: Introductionmentioning
confidence: 99%