1999
DOI: 10.1117/12.373311
|View full text |Cite
|
Sign up to set email alerts
|

Formation and detection of subpellicle defects by exposure to DUV system illumination

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
8
0

Year Published

2006
2006
2024
2024

Publication Types

Select...
4
4
1

Relationship

2
7

Authors

Journals

citations
Cited by 16 publications
(8 citation statements)
references
References 0 publications
0
8
0
Order By: Relevance
“…FTIR and Raman spectroscopy measurements have shown that ammonium sulfate comprises the highest content in the defect blend. [11][12] In the following sessions, we will discuss categories of commonly seen contamination defects to better understand the defects formation mechanism and how they evolve into printable defects depending upon the chemical and physical properties of the residing surface, along with how they behave with respect to Litho3 detector. For the purpose of this work, defects are categorized based on their location relative to the design features.…”
Section: Contamination Overviewmentioning
confidence: 99%
“…FTIR and Raman spectroscopy measurements have shown that ammonium sulfate comprises the highest content in the defect blend. [11][12] In the following sessions, we will discuss categories of commonly seen contamination defects to better understand the defects formation mechanism and how they evolve into printable defects depending upon the chemical and physical properties of the residing surface, along with how they behave with respect to Litho3 detector. For the purpose of this work, defects are categorized based on their location relative to the design features.…”
Section: Contamination Overviewmentioning
confidence: 99%
“…Over the last several years we have focused on understanding the relationships between lithographic exposure, cleaning and the chemical composition of the reticle surfaces, to include the quartz and metal surfaces and their effects on mask degradation and contamination, often referred to as haze [1][2][3] . The resulting work has allowed us to better understand the effects of micro-contamination on both the performance and life span of production reticles.…”
Section: Introductionmentioning
confidence: 99%
“…This gives rise to numerous challenges in the semiconductor wafer fabrication plants. Some of these challenges being: contamination (mainly haze [1,2] and particles), mask pattern degradation (MoSi oxidation [3], chrome migration [4], etc.) and pellicle degradation [5].…”
Section: Introductionmentioning
confidence: 99%