2017
DOI: 10.22270/jddt.v7i5.1498
|View full text |Cite
|
Sign up to set email alerts
|

Formulation and Evaluation of Oral Fast Dissolving Tablet of Ondansetron Hydrochloride by Coprocess Excipients

Abstract: Recent development in fast disintegrating technology mainly works to improve the quality of these delicate dosage forms without affecting their integrity. Current investigations deal with the formulation of fast dissolving tablet of Ondansetron HCl with the effect of different co-processed excipients by using ball mill that disintegrates in oral cavity on contact with saliva & thereby improve therapeutic efficacy because the mannitol was stick to dies and punch therefore ball mill is used to prepare co ground … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(5 citation statements)
references
References 1 publication
1
4
0
Order By: Relevance
“…Differential scanning calorimeter (DSC) analysis for ONDS (free form) powder showed a sharp endothermic peak at (235 ±1 °C), as shown in (Figure 3-A). Results indicated that ONDS was a pure crystalline powder which agreed with the reported studies [28]. In addition, CA analysis did not show a sharp endothermic peak, and a valley shape at (83 °C) indicates a transition temperature of CA which was related to its amorphous properties (Figure 3-B) [29].…”
Section: Thermal Analysissupporting
confidence: 88%
“…Differential scanning calorimeter (DSC) analysis for ONDS (free form) powder showed a sharp endothermic peak at (235 ±1 °C), as shown in (Figure 3-A). Results indicated that ONDS was a pure crystalline powder which agreed with the reported studies [28]. In addition, CA analysis did not show a sharp endothermic peak, and a valley shape at (83 °C) indicates a transition temperature of CA which was related to its amorphous properties (Figure 3-B) [29].…”
Section: Thermal Analysissupporting
confidence: 88%
“…The tablet is crack by rotating a threaded bolt, which force the upper plunger against the spring. The unit of measurement for facture force is kg/cm 2 [16] . 3.…”
Section: Formulation Of Fast Dissolving Tablets-mentioning
confidence: 99%
“…At various intervals, 10 ml samples were extracted and the volume of media was maintained by adding fresh media to the chamber. At 287 nm, the aliquots were analyzed spectrophotometrically for Ambrisentan [24].…”
Section: In Vitro Drug Release Studymentioning
confidence: 99%