2022
DOI: 10.1134/s2517751622020032
|View full text |Cite
|
Sign up to set email alerts
|

Fouling and Membrane Degradation in Electromembrane and Baromembrane Processes

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
12
0

Year Published

2022
2022
2025
2025

Publication Types

Select...
9

Relationship

1
8

Authors

Journals

citations
Cited by 43 publications
(14 citation statements)
references
References 251 publications
0
12
0
Order By: Relevance
“…The reproducibility variance values of the DP-sensors response are 10-27 mV 2 in solutions containing sulfanilamide, sulfacetamide, and NaOH with concentrations from 1.0 × 10 −4 to 1.0 × 10 −2 M. The DP-sensors do not contain components capable of leaching from the membrane. However, the membrane fouling is possible due to the accumulation of organic analyte ions in the pores, affecting the sorption and transport properties of membranes [39]. To eliminate it in DP-sensors, membranes in the K + -form were used.…”
Section: Stability and Reproducibility Of The Dp-sensorsmentioning
confidence: 99%
See 1 more Smart Citation
“…The reproducibility variance values of the DP-sensors response are 10-27 mV 2 in solutions containing sulfanilamide, sulfacetamide, and NaOH with concentrations from 1.0 × 10 −4 to 1.0 × 10 −2 M. The DP-sensors do not contain components capable of leaching from the membrane. However, the membrane fouling is possible due to the accumulation of organic analyte ions in the pores, affecting the sorption and transport properties of membranes [39]. To eliminate it in DP-sensors, membranes in the K + -form were used.…”
Section: Stability and Reproducibility Of The Dp-sensorsmentioning
confidence: 99%
“…A high mechanical and chemical stability of perfluorosulfonic acid membranes is an important factor for routine analysis. It provides their low proneness to fouling, fast and effective regeneration [39]. The possibility of simultaneous determination of dicarboxylic amino acid homologues in a wide pH range using an array of cross-sensitive DP-sensors (DP is the Donnan potential) based on the Nafion membranes and their Russian analogue MF-4SC membrane was shown elsewhere [40].…”
Section: Introductionmentioning
confidence: 99%
“…FO, MF, UF, gas separation and, especially, IEM in MBR, MMFC and other bioelectrochemical systems, as well as MCDI and ED modules, are subjected to intense chemical and biochemical fouling [ 90 , 211 , 212 ], which is well known and studied among “bottlenecks” of electromembrane systems and integrated with them processes. Indeed, the nutrient recovery is carried out from liquids that contain a large number of microorganisms or organic and inorganic substances that are a nutritional medium.…”
Section: Bottlenecks In Nutrient Recovery Processes Using Ion-exchang...mentioning
confidence: 99%
“…Due to the growing demand for the treatment of wastewater, recovery and concentration of valuable ion components [ 4 , 5 , 6 ], production of fertilizers [ 5 , 7 ], energy production by reverse electrodialysis [ 8 , 9 ] fuel cells [ 10 , 11 , 12 ], flow batteries [ 12 , 13 , 14 ] and other processes that involve IEM [ 15 , 16 , 17 , 18 ], the need for high-selective IEMs is growing rapidly.…”
Section: Introductionmentioning
confidence: 99%