Medical Imaging 2005: Physics of Medical Imaging 2005
DOI: 10.1117/12.594102
|View full text |Cite
|
Sign up to set email alerts
|

Four-arm variable-resolution x-ray detector for CT target imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
16
0

Year Published

2007
2007
2011
2011

Publication Types

Select...
4
2

Relationship

4
2

Authors

Journals

citations
Cited by 7 publications
(16 citation statements)
references
References 0 publications
0
16
0
Order By: Relevance
“…Nevertheless, in practice the difference in resolution in different regions of the image is not very significant. On the other hand, if the arms of a two-arm VRX system are placed asymmetrically around the main (F s C r ) axis, or if a symmetrical four-arm system with the inner arms located at smaller half-opening angles is used, the central region of the image (called the target zone) will have a considerably higher spatial resolution, while the system maintains a relatively large field of view [13]. show schematic representations of a four-arm targeting system, as well as two different two-arm targeting configurations.…”
Section: Targeting Vrx Scannersmentioning
confidence: 99%
See 4 more Smart Citations
“…Nevertheless, in practice the difference in resolution in different regions of the image is not very significant. On the other hand, if the arms of a two-arm VRX system are placed asymmetrically around the main (F s C r ) axis, or if a symmetrical four-arm system with the inner arms located at smaller half-opening angles is used, the central region of the image (called the target zone) will have a considerably higher spatial resolution, while the system maintains a relatively large field of view [13]. show schematic representations of a four-arm targeting system, as well as two different two-arm targeting configurations.…”
Section: Targeting Vrx Scannersmentioning
confidence: 99%
“…For example, the detectors in a four-arm system can be coupled to form a two-or even a single-arm system, and in multi-arm systems the arms can be placed in different positions to allow for target imaging. In target imaging, a region at the center of the image, known as the target zone, is imaged at a higher resolution while the external field of view remains large [13]. Target imaging with multi-arm VRX scanners is discussed in Section 3.1.3.…”
Section: Comparison Of Different Vrx Ct Implementations and Configuramentioning
confidence: 99%
See 3 more Smart Citations