2019
DOI: 10.1016/j.ica.2018.12.013
|View full text |Cite
|
Sign up to set email alerts
|

Four new luminescent-organic frameworks exhibiting highly sensing of nitroaromatics: An experimental and computational insight

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3

Citation Types

0
10
0

Year Published

2019
2019
2021
2021

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 17 publications
(10 citation statements)
references
References 64 publications
0
10
0
Order By: Relevance
“…Regarding this, Bauer et al [ 23 ] pointed out the importance of the design of LMOFs based on closed‐shell metal ions, also taking into account that it is possible to tune the linker‐centered emission by modifying the structure of the linker. This fact is mostly studied as this type of MOFs is unlikely to emit metal light as the Zn‐based and Cd‐based LMOFs reported by Lu et al [ 24 ] Based on these premises, Lustig et al [ 25 ] developed a series of LMOFs with ligand‐centered emission. They performed the modification of the linkers (tetrakis[4‐carboxyphenyl] ethylene) by both fluorination and elongation.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Regarding this, Bauer et al [ 23 ] pointed out the importance of the design of LMOFs based on closed‐shell metal ions, also taking into account that it is possible to tune the linker‐centered emission by modifying the structure of the linker. This fact is mostly studied as this type of MOFs is unlikely to emit metal light as the Zn‐based and Cd‐based LMOFs reported by Lu et al [ 24 ] Based on these premises, Lustig et al [ 25 ] developed a series of LMOFs with ligand‐centered emission. They performed the modification of the linkers (tetrakis[4‐carboxyphenyl] ethylene) by both fluorination and elongation.…”
Section: Introductionmentioning
confidence: 99%
“…From these results, researchers have proposed that the most probable PET mechanism is due to electron transfer from the conduction band (CB) of the MOF to the lowest unoccupied molecular orbital (LUMO) of NACs. [24,28] Nevertheless, as most of the theoretical reports deal with the computations of the MOF and analyte separately, which have limited the analysis to an orbital energy comparison between both structures, it becomes imperative to address the study of host-guest systems to design MOFs as sensors. This is a remarkable topic in the literature due to their role in changes on the photophysical properties that govern the recognition mechanisms of analytes.…”
mentioning
confidence: 99%
See 1 more Smart Citation
“…This fact is mostly studied since this type of MOFs are unlikely metal light emisor, as the Zn-based and Cd-based LMOFs reported by W. Liu and co-workers. 22 Based on these premises, Lustig et al (2016) 23 developed a series of LMOFs with ligand-centered emission. They performed the modification of the linkers (tetrakis(4-carboxyphenyl) ethylene) by both fluorination and elongation.…”
Section: Introductionmentioning
confidence: 99%
“…According to Zhong-Min (2014) 34 and Lu (2019) 22 from the point of view of the molecular orbitals, MOFs can be treated as discrete molecular systems. This fact is especially applicable in LMOFs based on d 10 metal, due that they present narrow band gaps energies and highly localized electronic states.…”
Section: Introductionmentioning
confidence: 99%