Fourier optics analysis of phase-mask-based path-length-multiplexed optical coherence tomography

Abstract: Optical coherence tomography (OCT) is an imaging technique that constructs a depth-resolved image by measuring the optical path-length difference between broadband light backscattered from a sample and a reference surface. For many OCT sample arm optical configurations, sample illumination and backscattered light detection share a common path. When a phase mask is placed in the sample path, features in the detected signal are observed, which suggests that an analysis of a generic common path OCT imaging system… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
6
1

Relationship

2
5

Authors

Journals

citations
Cited by 7 publications
(5 citation statements)
references
References 25 publications
0
5
0
Order By: Relevance
“…An integral component of the SAR-OCT system is a path length multiplexing element (PME), described in detail by Yin et al, 25 Wang et al, 11 and Gardner et al 13 The PME provides additional contrast to standard OCT images by separating sample path light into 3 different path lengths, each corresponding to a different angular range. Path length 1 ( L ; “Low”) is light that has scattered at generally low angles, whereas path lengths 2 ( H 2 ; “High 2”) and 3 ( H 3 ; “High 3”) contain light that has scattered at generally higher angles (Figure 2A).…”
Section: Methodsmentioning
confidence: 99%
“…An integral component of the SAR-OCT system is a path length multiplexing element (PME), described in detail by Yin et al, 25 Wang et al, 11 and Gardner et al 13 The PME provides additional contrast to standard OCT images by separating sample path light into 3 different path lengths, each corresponding to a different angular range. Path length 1 ( L ; “Low”) is light that has scattered at generally low angles, whereas path lengths 2 ( H 2 ; “High 2”) and 3 ( H 3 ; “High 3”) contain light that has scattered at generally higher angles (Figure 2A).…”
Section: Methodsmentioning
confidence: 99%
“…At each mode's focal plane, other modes present as a potential side-lobe or out-of-focus artifacts that could blur the in-focus mode. But since the SMF core spatially filters the backscattered light, off-axis scattering centers are strongly attenuated [20] and no significant side-lobe artifacts are observed as shown in Fig. 4 and Fig.…”
Section: Lateral Psf Artifactsmentioning
confidence: 97%
“…Thus, each sub image in the OCT interferogram is separated vertically by 2.5 mm. A more rigorous Fourier optical analysis of the PME operation for imaging was previously published [33]. A Monte Carlo model was developed to determine the effect of PME center aperture size on the intensity of light in each pathlength.…”
Section: Pathlength Multiplexing Elementmentioning
confidence: 99%