2018
DOI: 10.1016/j.arth.2017.09.066
|View full text |Cite
|
Sign up to set email alerts
|

Fourteen Year Follow-Up of Randomized Clinical Trials of Active Robotic-Assisted Total Hip Arthroplasty

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
69
0

Year Published

2018
2018
2022
2022

Publication Types

Select...
5
2
2

Relationship

0
9

Authors

Journals

citations
Cited by 67 publications
(70 citation statements)
references
References 30 publications
1
69
0
Order By: Relevance
“…Postoperative complications such as anterior femoral pain and early loosening of the prosthesis are common. Therefore, the optimal opening point of the femoral medullary cavity during hip replacement should be the posterior position of the top of the femoral neck cross-section [10][11][12] .…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Postoperative complications such as anterior femoral pain and early loosening of the prosthesis are common. Therefore, the optimal opening point of the femoral medullary cavity during hip replacement should be the posterior position of the top of the femoral neck cross-section [10][11][12] .…”
Section: Discussionmentioning
confidence: 99%
“…Relevant basic and clinical studies have found that the FNTA has important clinical significance in determining the spatial configuration of screws used for the internal fixation of femoral neck fractures and the screw hole design of the proximal femoral neck plate, as well as the proximal femoral medullary opening point and femoral prosthesis placement during hip joint replacement [6,[9][10][11][12][13] .…”
Section: Introductionmentioning
confidence: 99%
“…18 A study evaluating ROBODOC THA vs standard THA, with a mean follow-up of 14 years, showed no failures for stem loosening at a mean follow-up of 14 years and small but potentially important improvements in clinical outcomes in the robotic group. 19 The ROBODOC system is not without limitations. It requires increased time for planning, registration, and milling.…”
Section: Robodoc/tsolution Onetm Surgical Systemmentioning
confidence: 99%
“…But prior to this, FNTA was an underestimated anatomical parameter [7]. The current studies have found that the FNTA has important clinical significance in determining screw space configuration for internal fixation of femoral neck fractures, the screw hole design of the proximal femoral neck plate, and the proximal femoral medullary opening point and femoral prosthesis placement during hip joint replacement [6,[8][9][10][11][12]. Therefore, the accurate definition and measurement standard of the FNTA are important.…”
Section: Introductionmentioning
confidence: 99%