FPGA implementation of open-loop controller for five-level three phase modular multilevel converter

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
3
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
3
2

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(3 citation statements)
references
References 10 publications
0
3
0
Order By: Relevance
“…The operation of the open loop control system is based on the estimation of the total capacitor voltages via the stored energy in each arm's SMs, which is performed by measuring the other components and results in a less-complex interface with the regulator. The contribution of the voltage difference 𝑣𝑣 π‘‘π‘‘π‘‘π‘‘π‘Ÿπ‘Ÿπ‘Ÿπ‘Ÿ that must be deducted from the voltage reference 𝑒𝑒 𝑣𝑣 π‘Ÿπ‘Ÿπ‘Ÿπ‘Ÿπ‘Ÿπ‘Ÿ can be described as follows [86,98].…”
Section: Open Loop Control Techniquementioning
confidence: 99%
“…The operation of the open loop control system is based on the estimation of the total capacitor voltages via the stored energy in each arm's SMs, which is performed by measuring the other components and results in a less-complex interface with the regulator. The contribution of the voltage difference 𝑣𝑣 π‘‘π‘‘π‘‘π‘‘π‘Ÿπ‘Ÿπ‘Ÿπ‘Ÿ that must be deducted from the voltage reference 𝑒𝑒 𝑣𝑣 π‘Ÿπ‘Ÿπ‘Ÿπ‘Ÿπ‘Ÿπ‘Ÿ can be described as follows [86,98].…”
Section: Open Loop Control Techniquementioning
confidence: 99%
“…Focusing on harmonic estimation part, an open-loop controller is adopted to replace the PID controller for switching sequence generation, which was proved efficient as well especially with FPGA (field-programmable gate array) implementation [27]. For quasi-dynamic simulation in grid case studies, a close-loop controller can still be utilized, while its feedback period should be set long enough for the grid to move to another stable status.…”
Section: B MMC Operationmentioning
confidence: 99%
“…Regardless of the voltage balancing module, once the modulation scheme has been determined, combined with predictable U * p and U * w , switched U p and U w could be forecast. In accordance with such assumption, Focusing on harmonic estimation part, an open-loop controller is adopted to replace the PID controller for switching sequence generation, which was proved efficient as well especially with FPGA (field-programmable gate array) implementation [27]. For quasi-dynamic simulation in grid case studies, a close-loop controller can still be utilized, while its feedback period should be set long enough for the grid to move to another stable status.…”
Section: B MMC Operationmentioning
confidence: 99%