2019
DOI: 10.1111/jopr.13108
|View full text |Cite
|
Sign up to set email alerts
|

Fracture Resistance of Various Thickness e.max CAD Lithium Disilicate Crowns Cemented on Different Supporting Substrates: An In Vitro Study

Abstract: Purpose:To investigate the influence of abutment material properties on the fracture resistance and failure mode of lithium disilicate (IPS e.max) CAD/CAM (computeraided design/manufacturing) crowns on traditionally and minimally prepared simulated tooth substrates. Materials and Methods: Thirty lithium disilicate (IPS e.max) CAD/CAM crowns were divided into three groups (n = 10): TD: traditional thickness crowns cemented on Paradigm MZ100 abutments; MD: minimal thickness crowns cemented on Paradigm MZ100 abut… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
20
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 25 publications
(31 citation statements)
references
References 25 publications
1
20
0
Order By: Relevance
“…Their findings could be related to the different tooth type and the use of self-etch primer [5,9,36]. In addition, a high fracture resistance value was reported for lithium disilicate occlusal veneers, which could be attributed to the non-standardized protocol for cementation and difference in the thickness of the occlusal veneer [42,44,45].…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Their findings could be related to the different tooth type and the use of self-etch primer [5,9,36]. In addition, a high fracture resistance value was reported for lithium disilicate occlusal veneers, which could be attributed to the non-standardized protocol for cementation and difference in the thickness of the occlusal veneer [42,44,45].…”
Section: Discussionmentioning
confidence: 99%
“…The fracture resistance testing is crucial for determining how teeth react to highintensity loading [11,15,[42][43][44][45][46]. The aim of this research was to study how occlusal veneer materials (lithium disilicate, zirconia, and polymer-infiltrated ceramic) and dental bonding substrates (dentin, dentin with intra-coronal cavity, and dentin with composite filling) affected the fracture resistance and failure mode of mandibular molars restored with occlusal veneers.…”
Section: Introductionmentioning
confidence: 99%
“…The digital flow allows the standardization of all samples from both crowns and dies. The fracture resistance values of ceramic materials with lithium disilicate reinforcement can be affected depending on the substrate [33]. Considering this, the dies were designed in a standardized way and were resin-printed to approximate the elastic modulus of dentin and to simulate the clinical setting where restorations are performed.…”
Section: Discussionmentioning
confidence: 99%
“…Load-to-failure testing provides information at extreme conditions, therefore the findings of this in vitro study should not be directly related to clinical conditions. 21,22 The constant compressive load was applied until failure on the occlusal surface of the crowns in vertical direction to simulate the normal occlusal relationship of maxillary first premolar 23 for which a loading pattern that is vertical and along the long axis was demonstrated. 24,25 Regarding the effect of endodontic access cavity, differences in fracture strength of intact and repaired LD and RMC CAD/CAM crowns were not significant, suggesting that repair of the crown is feasible and replacement is not necessary.…”
Section: / Discussionmentioning
confidence: 99%