Abstract: Background:Frameless image-guided radiosurgery (IGRS) is a safe and effective noninvasive treatment for trigeminal neuralgia (TN). This study evaluates the use of frameless IGRS to treat patients with refractory TN.Methods:We reviewed the records of 20 patients diagnosed with TN who underwent frameless IGRS treatments between March 2012 and December 2013. Facial pain was graded using the Barrow Neurological Institute (BNI) scoring system. The initial setup uncertainty from simulation to treatment and the patie… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
8
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(8 citation statements)
references
References 36 publications
0
8
0
Order By: Relevance
“…A recent report of 138 cases using the CyberKnife for initial treatment of trigeminal neuralgia with a mean dose of 75 Gy had an effective pain control rate (BNI class I-IIIa) at six months of 93.5%, 12 months 85.8%, 24 months 79.7%, and at 36 months 76% [ 15 ]. As both clinical experience and the planning software and computer movement controls of these CK or LINAC systems have improved, the results for initial treatment of trigeminal neuralgia using equivalent dosing and targets are almost similar to the much larger reported GK experience [ 21 - 23 ]. As treatment teams, including the neurosurgeon, radiation oncologist, and radiation physicist, became more familiar with the treatment target and dose for trigeminal neuralgia, there are reports using different non-isocentric LINAC systems for the initial treatment of trigeminal neuralgia that match that achieved with both GK and CK [ 22 - 27 ].…”
Section: Introductionmentioning
confidence: 57%
“…A recent report of 138 cases using the CyberKnife for initial treatment of trigeminal neuralgia with a mean dose of 75 Gy had an effective pain control rate (BNI class I-IIIa) at six months of 93.5%, 12 months 85.8%, 24 months 79.7%, and at 36 months 76% [ 15 ]. As both clinical experience and the planning software and computer movement controls of these CK or LINAC systems have improved, the results for initial treatment of trigeminal neuralgia using equivalent dosing and targets are almost similar to the much larger reported GK experience [ 21 - 23 ]. As treatment teams, including the neurosurgeon, radiation oncologist, and radiation physicist, became more familiar with the treatment target and dose for trigeminal neuralgia, there are reports using different non-isocentric LINAC systems for the initial treatment of trigeminal neuralgia that match that achieved with both GK and CK [ 22 - 27 ].…”
Section: Introductionmentioning
confidence: 57%
“…SRS is a viable option for patients who do not attain durable pain relief from medications or who do not want or are not candidates for invasive surgery. [ 22 ] Gamma Knife,[ 2 , 25 , 29 ] CyberKnife,[ 5 , 6 , 29 ] and LINAC[ 4 , 5 , 8 - 10 , 14 , 24 , 26 , 29 ] are several modalities of SRS that are tolerable and efficacious for treating medically resistant TN. Leksell introduced the stereotactic method in 1951[ 16 ] and subsequently reported its use for patients with TN in 1971.…”
Section: Discussionmentioning
confidence: 99%
“…The immobilization, simulation, treatment planning, and SRS delivery methodology were previously published. [ 26 ] Patients were treated with 80, 85, or 90 Gy with a mode of 85 Gy. The dose was prescribed to a point in the trigeminal nerve so that at least the 60–80% isodose line encompassed the nerve.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Thus, verification imaging ensures that the patient is correctly aligned before treatment proceeds. While there are many reports in the literature discussing both frameless localization accuracy and intra-fraction motion [5][6][7][8], there has not been a detailed study of the correction threshold value used and its effect on treatment time and overall treatment uncertainty. The aim of the current study is to analyze the position data obtained from our TN treatments and evaluate the threshold value used for repositioning with respect to alignment uncertainty and positional correction frequency.…”
Section: Introductionmentioning
confidence: 99%