2020
DOI: 10.1049/iet-gtd.2019.1820
|View full text |Cite
|
Sign up to set email alerts
|

Frequency‐adaptive complex‐coefficient filter‐based control for grid‐integrated PV system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 8 publications
(7 citation statements)
references
References 24 publications
0
7
0
Order By: Relevance
“…The PV plant is operating at unity power factor, with its governing equations presented in the Appendix of this paper. In this study, the common incremental conductance (InC) maximum power point tracking algorithm [26] has been implemented for the PV inverter in order to obtain the dc‐link voltage reference set‐point. This method has advantage over the perturb and observe (P&O) algorithm that can show poor MPP tracking under extreme perturbations in irradiance.…”
Section: Test Studies Results and Discussionmentioning
confidence: 99%
“…The PV plant is operating at unity power factor, with its governing equations presented in the Appendix of this paper. In this study, the common incremental conductance (InC) maximum power point tracking algorithm [26] has been implemented for the PV inverter in order to obtain the dc‐link voltage reference set‐point. This method has advantage over the perturb and observe (P&O) algorithm that can show poor MPP tracking under extreme perturbations in irradiance.…”
Section: Test Studies Results and Discussionmentioning
confidence: 99%
“…Our focus in this section is to extend the self-tuning filter (9) for the unbalanced grid in the 𝛼𝛽 coordinate (5). To facilitate this, let us assume that the states are…”
Section: Proposed Extended Self-tuning Filtermentioning
confidence: 99%
“…Grid-interfacing converters (GIC) [1][2][3][4][5][6][7][8][9][10][11][12][13] are almost ubiquitous in today's modern power system. GICs are used to integrate distributed energy sources, generate DC voltage through active rectification of the grid voltage, improve the power quality through active power filtering, maintain constant voltage at the sensitive load, emulate the grid voltage for power converter testing etc.…”
Section: Introductionmentioning
confidence: 99%
“…In Ref. 37, it is suggested to regulate a grid integrated PV system using a CCF model. However, CCF is only used to trace the active load component, and a bandpass filter is employed to filter the grid voltage, which will not be effective for all adverse grid conditions.…”
Section: Introductionmentioning
confidence: 99%