2022
DOI: 10.1109/tste.2021.3102611
|View full text |Cite
|
Sign up to set email alerts
|

Frequency Dynamics-Constrained Parameter Design for Fast Frequency Controller of Wind Turbine

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
6
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 26 publications
(6 citation statements)
references
References 30 publications
0
6
0
Order By: Relevance
“…1, the mechanical power captured by the WT P Wm and the active power output by the WT P We can be expressed as (2). It should be noted that the AFC can be applied not only to WTs [19], but also to WFs [23]. To reduce computational burden for steadystate and dynamic analysis, the difference in operating state among WTs is ignored, and a single-machine aggregation model for the WF is adopted in this paper [21].…”
Section: Full-order Frequency Response Model For Multi-machine Power ...mentioning
confidence: 99%
See 1 more Smart Citation
“…1, the mechanical power captured by the WT P Wm and the active power output by the WT P We can be expressed as (2). It should be noted that the AFC can be applied not only to WTs [19], but also to WFs [23]. To reduce computational burden for steadystate and dynamic analysis, the difference in operating state among WTs is ignored, and a single-machine aggregation model for the WF is adopted in this paper [21].…”
Section: Full-order Frequency Response Model For Multi-machine Power ...mentioning
confidence: 99%
“…After establishing the frequency response model, the explicit expression of the frequency response indexes can be derived as a function of control coefficients in WF, thus the optimization scheme of the auxiliary frequency controller can be further studied. In order to improve the frequency support capability, the maximum rate of change of frequency (RoCoF) RoCoF max is regarded as an index for adjusting the coefficients of auxiliary frequency controller in [18] and [19]. These schemes ignore the time delay of the active power output by WF.…”
Section: Introductionmentioning
confidence: 99%
“…Instituting (3), (10), (11) into (9), the steady-state deviation of frequency response could be quantified by: * * 00 00 0 lim ( ) ( )…”
Section: B Performance Analysis Of Improved Sfr Model 1) Steady-state...mentioning
confidence: 99%
“…In order to secure the frequency stability, system operators design some frequency ancillary services procured from generators and demands, such as frequency containment reserve (FCR), frequency restoration reserve (FRR), and fast frequency reserve (FFR) in Denmark [6], [7]. Some clean alternative providers have been recommended to offer the frequency services for RES-dominated power systems, including the RES generation facilities [8], [9] and rapid responsive energy storages [10].…”
Section: Introductionmentioning
confidence: 99%
“…Inertia-based models [23,26,27] are mostly used to quantify the DFRC of restored systems. The quantification method of DFRC includes approximate linearization methods [26,28] and simulation methods [29,30]. However, since the inertia in HRPPSs is relatively low, inertia-based methods cannot accurately describe the DFRC of HRPPS.…”
Section: Introductionmentioning
confidence: 99%