Search citation statements
Paper Sections
Citation Types
Year Published
Publication Types
Relationship
Authors
Journals
PurposeOptimal head‐and‐neck cancer (HNC) treatment planning requires accurate and feasible planning goals to meet dosimetric constraints and generate robust online adaptive treatment plans. A new x‐ray‐based adaptive radiotherapy (ART) treatment planning system (TPS) version 2.0 emulator includes novel methods to drive the planning process including the revised intelligent optimization engine algorithm (IOE2). HNC is among the most challenging and complex sites and heavily depends on planner skill and experience to successfully generate a reference plan. Therefore, we evaluate the new TPS performance via conventionally accepted planning strategies with/without artificial intelligence (AI) and knowledge‐based planning (KBP).MethodsOur institution has a pre‐clinical release of the Varian Ethos2.0 TPS emulator which includes several changes that may affect current planning strategies. Twenty definitive and post‐operative HNC patients were retrospectively selected with a two or three‐level simultaneous integrated boost (SIB) dosing scheme. Patients were replanned in the emulator using population‐based, KBP‐guided with/without human intervention and AI‐guided planning goals. These planning strategies were compared both dosimetrically and for plan deliverability.ResultsAll strategies generally demonstrated acceptable plan quality with KBP‐ and AI‐guided goals offering enhanced dosimetric sparing in organs‐at‐risk (OAR). The average contralateral parotid gland mean dose was 20.0 ± 6.1 Gy (p < 0.001) for population‐based and 15.0 ± 6.1 Gy (p = n.s.) for KBP‐with human intervention versus 15.1 ± 7.4 Gy for clinical plans. Target coverage, minimum dose, and plan hotspot were acceptable in all cases. KBP‐enabled strategy demonstrated higher modulation and faster optimization time than both population‐based and AI‐guided strategies.ConclusionSimply entering population, automatic KBP‐enabled or AI‐generated planning goals into the new Ethos2.0 TPS produced dosimetrically compliant plans, with AI‐guided goals demonstrating the most OAR sparing. Several of these approaches are easy to translate to other treatment sites and will help lower the barrier to entry for x‐ray‐based online‐ART.
PurposeOptimal head‐and‐neck cancer (HNC) treatment planning requires accurate and feasible planning goals to meet dosimetric constraints and generate robust online adaptive treatment plans. A new x‐ray‐based adaptive radiotherapy (ART) treatment planning system (TPS) version 2.0 emulator includes novel methods to drive the planning process including the revised intelligent optimization engine algorithm (IOE2). HNC is among the most challenging and complex sites and heavily depends on planner skill and experience to successfully generate a reference plan. Therefore, we evaluate the new TPS performance via conventionally accepted planning strategies with/without artificial intelligence (AI) and knowledge‐based planning (KBP).MethodsOur institution has a pre‐clinical release of the Varian Ethos2.0 TPS emulator which includes several changes that may affect current planning strategies. Twenty definitive and post‐operative HNC patients were retrospectively selected with a two or three‐level simultaneous integrated boost (SIB) dosing scheme. Patients were replanned in the emulator using population‐based, KBP‐guided with/without human intervention and AI‐guided planning goals. These planning strategies were compared both dosimetrically and for plan deliverability.ResultsAll strategies generally demonstrated acceptable plan quality with KBP‐ and AI‐guided goals offering enhanced dosimetric sparing in organs‐at‐risk (OAR). The average contralateral parotid gland mean dose was 20.0 ± 6.1 Gy (p < 0.001) for population‐based and 15.0 ± 6.1 Gy (p = n.s.) for KBP‐with human intervention versus 15.1 ± 7.4 Gy for clinical plans. Target coverage, minimum dose, and plan hotspot were acceptable in all cases. KBP‐enabled strategy demonstrated higher modulation and faster optimization time than both population‐based and AI‐guided strategies.ConclusionSimply entering population, automatic KBP‐enabled or AI‐generated planning goals into the new Ethos2.0 TPS produced dosimetrically compliant plans, with AI‐guided goals demonstrating the most OAR sparing. Several of these approaches are easy to translate to other treatment sites and will help lower the barrier to entry for x‐ray‐based online‐ART.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
customersupport@researchsolutions.com
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
This site is protected by reCAPTCHA and the Google Privacy Policy and Terms of Service apply.
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.