Full-Scale Burst Test of Hydrogen Gas X65 Pipeline

Abstract: Full-scale burst test of X65 UOE linepipe, with 559mm outer diameter and 13.5mm wall thickness, pressurized at 16MPa by hydrogen gas was conducted. A 735mm long crack was introduced by explosive shaped charge over circumferential weld. The cracks were initiated and propagated in the both directions. The propagated crack lengths were 600mm and 270mm. J integral resistance curves were obtained from drop-weight as well as quasi static tests for the tested pipe material which was subjected to hydrogen charging. Th… Show more