1996
DOI: 10.1016/0731-7085(95)01688-0
|View full text |Cite
|
Sign up to set email alerts
|

Fully automated assay for the determination of sumatriptan in human serum using solid-phase extraction and high-performance liquid chromatography with electrochemical detection

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
17
0

Year Published

2000
2000
2013
2013

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 30 publications
(17 citation statements)
references
References 3 publications
0
17
0
Order By: Relevance
“…In this study, fluorescence detection was used instead of coulometric detection [5][6][7][8] or mass spectrometry detection [9,10]. This mode of detection is simple, stable, robust and gave a similar limit of quantitation (1 ng/ml when using 0.5 ml of plasma) to those previously published methods.…”
Section: Discussionmentioning
confidence: 90%
See 1 more Smart Citation
“…In this study, fluorescence detection was used instead of coulometric detection [5][6][7][8] or mass spectrometry detection [9,10]. This mode of detection is simple, stable, robust and gave a similar limit of quantitation (1 ng/ml when using 0.5 ml of plasma) to those previously published methods.…”
Section: Discussionmentioning
confidence: 90%
“…Among the methods described in the literature, there is high performance liquid chromatography (HPLC) with coulometric detection [5][6][7][8] and HPLC with mass spectrometric detection [9][10][11]. In these methods, the sumatriptan was extracted from plasma samples using liquid-liquid extraction or solid phase extraction.…”
Section: Introductionmentioning
confidence: 99%
“…Several methods are reported for the determination of SUM in biological matrices by HPLC with fluorescence [9,10], electrochemical [11][12][13], ultraviolet detection [14,15] and LC-MS/MS [16][17][18][19][20][21][22]. In majority of these published methods, the sensitivity was ≥1 ng/mL [9][10][11][12]16,20,22] with high volume of biological fluid (≥0.5 mL) for sample processing [9][10][11][12][13]16,17,[19][20][21].…”
Section: Introductionmentioning
confidence: 97%
“…Other assays for compounds of this class such as Sumatriptan [2] have been developed using electrochemical detection, the presence of the indole moiety in the compound facilitates this [3]. HPLC with electrochemical detection was investigated for CP-122,288 in plasma but even with extensive sample preparation techniques, chemical noise and baseline instability compromised the robustness of such an assay approach.…”
mentioning
confidence: 98%