2012
DOI: 10.1039/c2ja10304d
|View full text |Cite
|
Sign up to set email alerts
|

Fully automated lab-on-valve-multisyringe flow injection analysis-ICP-MS system: an effective tool for fast, sensitive and selective determination of thorium and uranium at environmental levels exploiting solid phase extraction

Abstract: An on-line solid-phase extraction method linked to inductively coupled mass spectrometry (ICP-MS) has been developed for the determination of low levels of uranium and thorium in environmental samples. The hyphenation of lab-on-valve (LOV) and multisyringe flow injection analysis (MSFIA), coupled to an ICP-MS, allows the simultaneous determination of thorium and uranium in different types of environmental sample matrices achieving high selectivity and sensitivity levels. On-line separation and preconcentration… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
32
0
1

Year Published

2014
2014
2024
2024

Publication Types

Select...
9
1

Relationship

1
9

Authors

Journals

citations
Cited by 76 publications
(33 citation statements)
references
References 24 publications
0
32
0
1
Order By: Relevance
“…The method detection limit was 0.5 ng L À1 (2.0 Â 10 À6 Bq g À1 ) Avivar et al (2011) measured Th and U in multiple environmental samples (different water samples, a phosphogypsum sample, and a channel sediment reference material) using multi-syringe FIA (MSFIA), using UTEVA resin (Triskem International) for online separation and pre-concentration. 248 The system was coupled to ICP-DRC-MS (Perkin Elmer Elan DRC-e) equipped with a Scott spray chamber and cross-ow nebulizer. Combination of LOV with MSFIA achieved a 232 Th detection limit of 2.8 ng L À1 (1.1 Â 10 À5 Bq L À1 ), compared to 120 ng L À1 (4.9 Â 10 À4 Bq L À1 ) using FIA only.…”
Section: Thorium Isotopesmentioning
confidence: 99%
“…The method detection limit was 0.5 ng L À1 (2.0 Â 10 À6 Bq g À1 ) Avivar et al (2011) measured Th and U in multiple environmental samples (different water samples, a phosphogypsum sample, and a channel sediment reference material) using multi-syringe FIA (MSFIA), using UTEVA resin (Triskem International) for online separation and pre-concentration. 248 The system was coupled to ICP-DRC-MS (Perkin Elmer Elan DRC-e) equipped with a Scott spray chamber and cross-ow nebulizer. Combination of LOV with MSFIA achieved a 232 Th detection limit of 2.8 ng L À1 (1.1 Â 10 À5 Bq L À1 ), compared to 120 ng L À1 (4.9 Â 10 À4 Bq L À1 ) using FIA only.…”
Section: Thorium Isotopesmentioning
confidence: 99%
“…The system was fitted with a Scott spray chamber and a crossflow nebulizer (Perkin Elmer, Spain). 209 Bi and 107 Ag (2 mg L À 1 ) were used as internal standards (Feuerstein et al, 2008;Avivar et al, 2012) to compensate for the instrument drift between runs.…”
Section: Instrumentationmentioning
confidence: 99%
“…A fully automated LOVeMSFIAeICP-MS system was proposed as a fast, sensitive and selective methodology for determination of thorium and uranium at environmental levels [27]. Both radionuclides have natural radioisotopes with long half-lives, e.g.…”
Section: Icp-ms For Radioisotope Determinationsmentioning
confidence: 99%