2019
DOI: 10.1111/1751-2980.12818
|View full text |Cite
|
Sign up to set email alerts
|

Functional lumen imaging probe in gastrointestinal motility diseases

Abstract: Dysfunction of gastrointestinal (GI) sphincters, including the lower esophageal sphincter (LES) at the esophagogastric junction (EGJ) and the pyloric sphincter, plays a vital role in GI motility disorders, such as achalasia, gastroesophageal reflux disease (GERD), gastroparesis, and fecal incontinence. Using multi‐detector high‐resolution impedance planimetry, the functional luminal imaging probe (FLIP) system measures simultaneous data on tissue distensibility and luminal geometry changes in the sphincter in … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
3
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 50 publications
0
3
0
Order By: Relevance
“…The data by FLIP can be objectively interpreted in real-time, is less operator dependent, and allows for a more complete picture of esophageal physiology as compared to HRM. It can also predict the clinical outcomes of myotomy, whether done surgically or endoscopically [ 14 ]. The data on the LES makes FLIP particularly useful in the evaluation of achalasia and esophagogastric junction outflow obstruction (EGJOO), as these may be associated with DES [ 1 ].…”
Section: Reviewmentioning
confidence: 99%
“…The data by FLIP can be objectively interpreted in real-time, is less operator dependent, and allows for a more complete picture of esophageal physiology as compared to HRM. It can also predict the clinical outcomes of myotomy, whether done surgically or endoscopically [ 14 ]. The data on the LES makes FLIP particularly useful in the evaluation of achalasia and esophagogastric junction outflow obstruction (EGJOO), as these may be associated with DES [ 1 ].…”
Section: Reviewmentioning
confidence: 99%
“…The commercially available Endoflip system utilizes a 25 mm bag (Catheter 325N) that is used primarily for testing distensibility of the esophagus, lower esophageal sphincter, and anal sphincter. [11][12][13] We used a modified, custom designed Endoflip bag of 30 mm diameter with a larger bore catheter for injection of fluid into the bag.…”
Section: Concentric Endoflip Exercise Protocolmentioning
confidence: 99%
“…There is a significant amount of literature describing the use of FLIP in adult patients with achalasia that supports its potential benefit in pediatrics [19,20]. At CHOP, FLIP is used to measure EGJ distensibility prior to an immediately after a balloon dilatation in patients with achalasia using the EF-325N catheter.…”
Section: Site Experiencesmentioning