Inductively Coupled Plasma Spectrometry and Its Applications 2006
DOI: 10.1002/9780470988794.ch2
|View full text |Cite
|
Sign up to set email alerts
|

Fundamental Principles of Inductively Coupled Plasmas

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
7
0

Year Published

2008
2008
2017
2017

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 188 publications
0
7
0
Order By: Relevance
“…Higher Η β /H α ratio means higher population at higher excited levels, which also indicated higher electron energy if assuming that the excitation of H atoms is mainly caused by electron impact. More accurately, the emission intensity could be written as I j k = A j k g j λ j k exp true( E j E k k B T e true) where I j → k is the line intensity corresponding to the transition from higher energy level j to lower one k , A jk is the corresponding transition probability, λ jk is the wavelength of the transition, E j − E k is the energy difference between level j and level k , g j is the statistic weight (or degeneracy) of the higher energy level, k B is the Boltamann constant, and T e is the electron temperature.…”
Section: Resultsmentioning
confidence: 99%
“…Higher Η β /H α ratio means higher population at higher excited levels, which also indicated higher electron energy if assuming that the excitation of H atoms is mainly caused by electron impact. More accurately, the emission intensity could be written as I j k = A j k g j λ j k exp true( E j E k k B T e true) where I j → k is the line intensity corresponding to the transition from higher energy level j to lower one k , A jk is the corresponding transition probability, λ jk is the wavelength of the transition, E j − E k is the energy difference between level j and level k , g j is the statistic weight (or degeneracy) of the higher energy level, k B is the Boltamann constant, and T e is the electron temperature.…”
Section: Resultsmentioning
confidence: 99%
“…Natural broadening is on the order of hundreds of picometres (pm) and a 0.05 pm broadening would produce only a 0.04% error in this estimate [33], so this contribution can be neglected. Pressure broadening in inductively coupled plasmas (ICP), which are comparable to PEO plasmas in terms of temperature and pressure, is only a few picometres [34]. A 5.0 pm contribution from pressure broadening would produce a 4% error [34], which was judged to be acceptable and, ultimately, was several times smaller than the experimental uncertainty.…”
Section: Electron Concentration and Temperaturementioning
confidence: 99%
“…Pressure broadening in inductively coupled plasmas (ICP), which are comparable to PEO plasmas in terms of temperature and pressure, is only a few picometres [34]. A 5.0 pm contribution from pressure broadening would produce a 4% error [34], which was judged to be acceptable and, ultimately, was several times smaller than the experimental uncertainty. The electron concentration measurement error (δN e /N e ) was estimated to be ≈15%, which is a reasonable value in such experiments.…”
Section: Electron Concentration and Temperaturementioning
confidence: 99%
“…The production of 40 Ar 4+ is, to a large extent, controlled by plasma temperature, which in turn is affected by parameters such as RF power, sample gas ow, solvent loading and RF generator characteristics. 45 Gäbler and Bahr 11 reported that the intensity of 40 Ar 4+ interference can be reduced by using a lower radio frequency setting, which is one of the fundamental parameters that inuence the ICP temperature. The results of our study are consistent with those in ref.…”
Section: A Laser Ablation MC Icp-ms Matrix Effectsmentioning
confidence: 99%