2013
DOI: 10.1140/epja/i2013-13128-2
|View full text |Cite
|
Sign up to set email alerts
|

GARFIELD + RCo digital upgrade: A modern set-up for mass and charge identification of heavy-ion reaction products

Abstract: An upgraded GARFIELD + Ring Counter (RCo) apparatus is presented with improved performances as far as electronics and detectors are concerned. On one side fast sampling digital read out has been extended to all detectors, allowing for an important simplification of the signal processing chain together with an enriched extracted information. On the other side a relevant improvement has been made in the forward part of the setup (RCo): an increased granularity of the CsI(Tl) crystals and a higher homogeneity in … Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
25
0

Year Published

2014
2014
2022
2022

Publication Types

Select...
9

Relationship

7
2

Authors

Journals

citations
Cited by 46 publications
(26 citation statements)
references
References 50 publications
1
25
0
Order By: Relevance
“…As explained in greater details in paper I, we have measured the 12 C+ 12 C reaction at 95 MeV with the GARFIELD+RCo set-up [16]. We have selected a data-set consisting of events completely detected in charge (Z tot = 12) which corresponds to a large extent to the complete fusion-evaporation channel.…”
Section: Deviations From a Statistical Behaviourmentioning
confidence: 99%
“…As explained in greater details in paper I, we have measured the 12 C+ 12 C reaction at 95 MeV with the GARFIELD+RCo set-up [16]. We have selected a data-set consisting of events completely detected in charge (Z tot = 12) which corresponds to a large extent to the complete fusion-evaporation channel.…”
Section: Deviations From a Statistical Behaviourmentioning
confidence: 99%
“…The experimental apparatus consists of the multidetector GARFIELD and Ring Counter, located in the Hall III of Laboratori Nazionali di Legnaro (LNL): a complete description and details can be found elsewhere [18]. Briefly, GARFIELD is a twostage detector consisting of two identical microstrip gas chambers (the E stage) and CsI(Tl) crystals (for residual particle energy).…”
Section: Experimental Apparatusmentioning
confidence: 99%
“…In particular, one of the traditional fields is the study of nuclei under extreme conditions, that is the study of the evolution of nuclear structure towards the region far from stability in terms of excitation energy (decay and behaviour of hot nuclei), high spin states (highly rotating nuclei), and, finally, high isospin (high N over Z ratio). Large efforts are devoted to the upgrading of installed experimental set-ups (PRISMA [13], GARFIELD [14], etc.). The developments of new instrumentation (AGATA [16], NEDA [19], FAZIA [18], GALILEO [15], ATS − ACTAR [17], PARIS [20], TRACE [21], etc.)…”
Section: Spes Instrumentation and Scientific Programmentioning
confidence: 99%
“…Large efforts are devoted to the upgrading of installed experimental set-ups (PRISMA [13], GARFIELD [14], etc.). The developments of new instrumentation (AGATA [16], NEDA [19], FAZIA [18], GALILEO [15], ATS − ACTAR [17], PARIS [20], TRACE [21], etc.) are also performed within international collaborations in order to carry out up-to-date experimentation at SPES, as it was recently discussed in the 2 nd International SPES Workshop (May 26-28, 2014), where about 40 Letters of Intents have been presented and discussed with the Scientific Advisory Commitee [22].…”
Section: Spes Instrumentation and Scientific Programmentioning
confidence: 99%