1996
DOI: 10.1016/0021-9673(96)00465-7
|View full text |Cite
|
Sign up to set email alerts
|

Gas chromatographic-tandem mass spectrometric analysis of clenbuterol residues in faeces

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
14
0

Year Published

1999
1999
2018
2018

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 17 publications
(15 citation statements)
references
References 14 publications
1
14
0
Order By: Relevance
“…Although methods used to extract and quantitate b-agonists have been described in recent publications (Abou-Basha and AboulEnein, 1996;Girault and Fourtillan, 1990;Sangiorgi and Curatolo, 1997;Kingston et al, 1995;Blanchflower et al, 1993;Garcia-Regueiro et al, 1993;Batjoens et al, 1996;Gigosos et al, 1996;Wilson et al, 1994), quantitation of clenbuterol in biological fluids still remains a challenge. This is, in part, due to the close proximity of the two halogen atoms to the amino and hydroxyl functional groups of the clenbuterol molecule, rendering efficient derivatization for the GC-MS quantitation difficult (Abukhalaf et al, 1999).…”
Section: Resultsmentioning
confidence: 98%
See 3 more Smart Citations
“…Although methods used to extract and quantitate b-agonists have been described in recent publications (Abou-Basha and AboulEnein, 1996;Girault and Fourtillan, 1990;Sangiorgi and Curatolo, 1997;Kingston et al, 1995;Blanchflower et al, 1993;Garcia-Regueiro et al, 1993;Batjoens et al, 1996;Gigosos et al, 1996;Wilson et al, 1994), quantitation of clenbuterol in biological fluids still remains a challenge. This is, in part, due to the close proximity of the two halogen atoms to the amino and hydroxyl functional groups of the clenbuterol molecule, rendering efficient derivatization for the GC-MS quantitation difficult (Abukhalaf et al, 1999).…”
Section: Resultsmentioning
confidence: 98%
“…Some of these reports, however, utilize GC-MS-MS systems which are not commonly available in many laboratories (Garcia-Regueiro et al, 1993;Kingston et al, 1995;Batjoens et al, 1996). Additionally, methods utilizing electron impact GC-MS systems with silylation and/or acetylation derivatization reactions were unable to generate ions with sufficient intensity other than the m/z 86 (Branum et al, 1998).…”
Section: Introductionmentioning
confidence: 90%
See 2 more Smart Citations
“…In this situation the matrix and the chemical background can easily interfere, leading to possible misinterpretations. To overcome these difficulties, some alternatives are introduced by employing two different derivatizing agents 9 or two different ion sources 10 or by performing the analysis in the MS/MS mode.…”
Section: Introductionmentioning
confidence: 99%