1998
DOI: 10.1021/ac970776r
|View full text |Cite
|
Sign up to set email alerts
|

Gas Chromatography as a Reference Method for Moisture Determination by Near-Infrared Spectroscopy

Abstract: Near-infrared spectroscopic (NIRS) methods were developed to determine moisture in freeze-dried drug products with gas chromatography as the reference measurement. The gas chromatography method was optimized to provide a relative standard deviation of 1.1%. Because NIRS calibration models are limited by the quality of the reference measurement, all aspects of the GC technique were studied, including water standard preparation, operating conditions, and sample treatment. Vials of a freeze-dried drug product wer… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
12
0

Year Published

2001
2001
2014
2014

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 22 publications
(12 citation statements)
references
References 11 publications
0
12
0
Order By: Relevance
“…Near infrared spectroscopy (NIRS) has found diverse applications for rapid and nondestructive analysis 4. It is especially suitable for moisture determination because water has strong absorption bands in the near infrared region that provide the sensitivity needed for accurate determinations 1–6. NIRS methods for water determination have been demonstrated to be not only rapid and nondestructive, with no sample pretreatment, but also highly accurate 5,6.…”
Section: Introductionmentioning
confidence: 99%
“…Near infrared spectroscopy (NIRS) has found diverse applications for rapid and nondestructive analysis 4. It is especially suitable for moisture determination because water has strong absorption bands in the near infrared region that provide the sensitivity needed for accurate determinations 1–6. NIRS methods for water determination have been demonstrated to be not only rapid and nondestructive, with no sample pretreatment, but also highly accurate 5,6.…”
Section: Introductionmentioning
confidence: 99%
“…1. 27,28 Based on the absorption features observed in the NIR spectra, the two spectral ranges chosen to establish the calibration model were: 5980-5650 cm -1 and 5200-4935 cm -1 . 27,28 Based on the absorption features observed in the NIR spectra, the two spectral ranges chosen to establish the calibration model were: 5980-5650 cm -1 and 5200-4935 cm -1 .…”
Section: Resultsmentioning
confidence: 99%
“…moisture determination via Karl Fischer), loss on drying (LOD) or GC. 35 If toxicity is a concern, then in -process sampling needs to be either reduced or removed. Within this section on -line spectroscopic dryer monitoring will be discussed, including (1) moisture determination via direct contact with the drug substance and (2) moisture/ solvent determination via effl uent monitoring.…”
Section: Api Dryingmentioning
confidence: 99%