Gas Chromatography-Ion Mobility Spectrometry Instrument for Medical Applications: A Calibration Protocol for ppb and ppt Concentration Range

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
6
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4

Relationship

3
1

Authors

Journals

citations
Cited by 4 publications
(6 citation statements)
references
References 12 publications
0
6
0
Order By: Relevance
“…A third coordinate, corresponding to the intensity (volts) of each ion detected by the detector placed at the end of the drift tube, is equally represented. These intensity levels are directly related to the original concentrations that each molecule presented in the original sample and can be used for plotting calibration curves and quantifying the detected analytes [ 32 ]. Figure 2 schematizes an arbitrary three-dimensional GC-IMS spectrum in a two-dimensional view.…”
Section: Methodsmentioning
confidence: 99%
“…A third coordinate, corresponding to the intensity (volts) of each ion detected by the detector placed at the end of the drift tube, is equally represented. These intensity levels are directly related to the original concentrations that each molecule presented in the original sample and can be used for plotting calibration curves and quantifying the detected analytes [ 32 ]. Figure 2 schematizes an arbitrary three-dimensional GC-IMS spectrum in a two-dimensional view.…”
Section: Methodsmentioning
confidence: 99%
“…These 5 cm length tubes were maintained in a thermogravimetric device for an accurate control of temperature (40,60, and 85 • C ) and flow (25, 50, 100, 150, and 200 mL∕min ). VOCs were, then, analyzed by GC-IMS [99].…”
Section: Vocs Identification Through Imsmentioning
confidence: 99%
“…26, and to the formation equation of the 2-hexanone dimer, Eq. 27 [99]. ( 26) As mentioned, IMS devices that use a radioactive ionization source have a limitation in analyzing higher concentrations.…”
Section: Vocs Quantification Through Imsmentioning
confidence: 99%
See 1 more Smart Citation
“…To do so, a calibration protocol previously developed was applied to our data. Further details regarding the developed methodology can be consulted elsewhere [53,55]; nevertheless, it is important to emphasize the The more relevant volatile organic compounds in this profile are compounds 10 (2butanone) and 26 (not identified), which are around 14 and 24 times more intense in the interior of the office than they are in the outdoor samples. Compounds 1 (ethanol), 21, and 22 (not identified) have relative intensities between 4 and 6, and compounds 4 (acetone) and 15 (2-hexanone) are two times more intense in the indoor air than outside.…”
Section: Vocs Quantificationmentioning
confidence: 99%