2006
DOI: 10.2116/analsci.22.1483
|View full text |Cite
|
Sign up to set email alerts
|

Gas Chromatography/Multiphoton Ionization/Mass Spectrometry of Polychlorinated Dibenzofurans Using Nanosecond and Femtosecond Lasers

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
19
0

Year Published

2007
2007
2010
2010

Publication Types

Select...
8

Relationship

5
3

Authors

Journals

citations
Cited by 23 publications
(20 citation statements)
references
References 25 publications
1
19
0
Order By: Relevance
“…7,12,18 One microliter of the sample solution was injected into a GC system (Agilent Technologies, 6890N) using an auto-sampler (Agilent Technologies, 7683B), followed by separation using an HP-5 capillary column (length, 30 m; i.d., 0.32 mm). Helium was used as a carrier gas at a constant flow rate of 1 mL/min.…”
Section: Gc/rempi-tofmsmentioning
confidence: 99%
See 1 more Smart Citation
“…7,12,18 One microliter of the sample solution was injected into a GC system (Agilent Technologies, 6890N) using an auto-sampler (Agilent Technologies, 7683B), followed by separation using an HP-5 capillary column (length, 30 m; i.d., 0.32 mm). Helium was used as a carrier gas at a constant flow rate of 1 mL/min.…”
Section: Gc/rempi-tofmsmentioning
confidence: 99%
“…A laser with a short pulse duration has been utilized for the ionization of aromatic compounds. 10,11 For example, a femtosecond laser was successfully used for the efficient ionization of chlorinated and brominated PAHs 12,13 before relaxation by internal conversion and intersystem crossing to triplet levels. Unfortunately, the size, monetary cost, and difficulties associated with the maintenance and operation of such lasers prevent the practical use of this method in environmental analysis.…”
Section: Introductionmentioning
confidence: 99%
“…Thus, the wavelength of the 0-0 transition was increased in the order of o-, m-and p-ethylphenol, which is identical to the order of o-, m-and p-chlorophenols. 15 This result could be explained by the fact that both compounds have an electron-donating substituent in a molecule.…”
Section: Rempi Spectra Of O- M-and P-ethylphenolsmentioning
confidence: 99%
“…It is sensitive and useful when combined with TOFMS, the so‐called MPI/TOFMS. This is particularly useful, when a femtosecond laser is used in conjunction with the MPI/TOFMS technique, the ionization efficiency can be improved significantly 1–4. With such a superior characteristic, the measurements of dioxin precursors and non‐chlorinated aromatic compounds have been reported 5–7.…”
Section: Introductionmentioning
confidence: 99%