Gas-lens effect and cavity design of some frequency-stabilized He–Ne lasers

Abstract: It is shown that there exists an optimal cavity length which should minimize the frequency shifts induced by lenslike effects in intracavity saturated absorption lasers. Ideas are developed which provide a satisfactory explanation for the dispersion in modulation shifts observed in some recent laser intercomparisons.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
25
0

Year Published

1987
1987
2023
2023

Publication Types

Select...
5
1

Relationship

0
6

Authors

Journals

citations
Cited by 46 publications
(27 citation statements)
references
References 13 publications
2
25
0
Order By: Relevance
“…It is important to note that this effect has already been accidentally observed [27,28]. It is also important to highlight that to the best of our knowledge, no theoretical explanation has been given to such effect.…”
Section: Introductionmentioning
confidence: 78%
See 2 more Smart Citations
“…It is important to note that this effect has already been accidentally observed [27,28]. It is also important to highlight that to the best of our knowledge, no theoretical explanation has been given to such effect.…”
Section: Introductionmentioning
confidence: 78%
“…Line shape at the output 2 (c) with its zoomed view (d). [16,26,27]. In these conditions, his Lamb-dip frequency is coincident with the resonance frequency.…”
Section: Experimental Studymentioning
confidence: 91%
See 1 more Smart Citation
“…The curvature radius of the laser mirror is 7 m for the methane cell side and 2 m for the other side. Therefore a beam waist in a laser cavity without the gas lens effects [5] has been calculated to be very close to the center of the methane cell. On the other hand, a transmittance of the laser mirror is, respectively, 2 percent for the cell side and 5 percent for the other side.…”
Section: The Systemmentioning
confidence: 99%
“…The Allan variance in the stabilized case increases for an average time of shorter than 10 ms owing to an effect of a modulation. But it decreases with 10-1 10' Averaging Time (5) an inclination of 2.5 x 10-12 7 -1 / 2 between 10 ms and 1000 s. The frequency difference between two stabilized lasers which were continuously operated for six days (from February 24, 1986) was measured at the same time during each day. The results are the mean values of 20 samples measured at I-s gate time.…”
Section: Two Stabilized Lasers As Shown Inmentioning
confidence: 99%