Gas-Phase Reactions of Transition-Metal Ions with Molecular Oxygen:  Room-Temperature Kinetics and Periodicities in Reactivity

Abstract: An Inductively-Coupled Plasma/Selected-Ion Flow Tube (ICP/SIFT) tandem mass spectrometer has been employed in a systematic survey of room-temperature reactions of O 2 with 29 transition-metal ions. The atomic ions are produced at ca. 5500 K in an ICP source and are allowed to decay radiatively and to thermalize by collisions with Ar and He atoms prior to reaction. Rate coefficients were measured for the reactions of first-row atomic ions from Sc + to Zn + , of second-row atomic ions from Y + to Cd + (excluding… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

9
131
1
3

Year Published

2003
2003
2018
2018

Publication Types

Select...
5
3

Relationship

1
7

Authors

Journals

citations
Cited by 129 publications
(144 citation statements)
references
References 32 publications
9
131
1
3
Order By: Relevance
“…When an element of the fifth period was included in a target system, another calculation model, less precise than the DFT, was used for calculation of the energies of the whole reaction even though the energy of oxygen could be calculated precisely by DFT. Published thermochemistry data [26][27][28][29]44 are shown together with the results in order to validate the calculations.…”
Section: Theoretical Calculationmentioning
confidence: 99%
See 1 more Smart Citation
“…When an element of the fifth period was included in a target system, another calculation model, less precise than the DFT, was used for calculation of the energies of the whole reaction even though the energy of oxygen could be calculated precisely by DFT. Published thermochemistry data [26][27][28][29]44 are shown together with the results in order to validate the calculations.…”
Section: Theoretical Calculationmentioning
confidence: 99%
“…[26][27][28][29] Although these recent discussions of reaction cell mechanisms might be thought sufficient, there is a lack of consideration of reaction systems and reaction routes and a reliance on reference data rather than calculation of data specific to the systems under investigation. In addition, although ions are detected in ICP-MS analysis, there is a lack of thermal energy data for the ions.…”
Section: Introductionmentioning
confidence: 99%
“…3 Bohme 2013 argues the plausibility of (5)-(6) by citing analogous reactions reported by their group involving NO 2 and O 2 . 4,5 Our argument against the three-body mechanism for Fe + + NO is based on the time scale of the reaction specific to that system, depending on the vibrational and rotational frequencies and, significantly, on the dissociation energy of the complex. Os + -O 2 is bound by ~5eV, 6 which is a value given in our original paper that would make Fe + -NO stable enough for the termolecular mechanism to proceed.…”
Section: Fe + + No + (No He) → Feno + + (No He)mentioning
confidence: 99%
“…Indeed, stable OsO 2 + is observed. 4 (Metal-NO 2 ) + complexes are characterized by more low energy modes than those for (Metal-NO) + ones and may be more stable. Both effects result in an upper limit on the threebody mechanism that is several orders of magnitude higher than that for the termolecular NO mechanism.…”
Section: Fe + + No + (No He) → Feno + + (No He)mentioning
confidence: 99%
“…Reaction cell technique offers an effective approach for the separation of spectral interferences in the measurement by ICP-MS. 15 In order to achieve specific separations of various spectral interferences, some kinds of gases had been explored as the reaction gas in the reaction cell of ICP-MS, including H 2 , O 2 , NH 3 , CH 3 F, N 2 H 6 , N 2 O, CO, NO, and SF 6 . 5 A systematic investigation of the ion-molecule reactions in the reaction cell will provide useful information for the development of a method for separating spectral interferences.…”
mentioning
confidence: 99%