2023
DOI: 10.3390/waste1020031
|View full text |Cite
|
Sign up to set email alerts
|

Gasification of Waste Machine Oil by the Ultra-Superheated Mixture of Steam and Carbon Dioxide

Sergey M. Frolov,
Anton S. Silantiev,
Ilias A. Sadykov
et al.

Abstract: Reported in the article is further progress in the development of the novel pulsed detonation gun (PDG) technology for the conversion of organic wastes into syngas in a two-component gasifying agent (GA) containing ultra-superheated steam and carbon dioxide obtained by pulsed detonations of a natural gas–oxygen mixture at a frequency of 1 Hz. Experimental studies were carried out on a waste converter with a 40 dm3 flow reactor and two PDGs with a total volume of 2.4 or 3.2 dm3, which is approximately a factor … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
2

Relationship

2
0

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 36 publications
0
5
0
Order By: Relevance
“…When analyzing the data in Table 1, the following observations are worth mentioning. Firstly, the WO/GA mass ratio in the experiments [37] varied from 0.75 to 1.18, which was considerably larger than the value of WO/GA = 0.45 ensuring the maximum content of H 2 in the produced syngas according to Figure 7. Secondly, the measured wall temperature of the gasifier (=823-873 K) is seen to be 150-180 K less than the calculated equilibrium temperature of the gasification products (about 1000 K), which looks reasonable as the gasifier was not thermally insulated in the experiments.…”
Section: Modelmentioning
confidence: 94%
See 3 more Smart Citations
“…When analyzing the data in Table 1, the following observations are worth mentioning. Firstly, the WO/GA mass ratio in the experiments [37] varied from 0.75 to 1.18, which was considerably larger than the value of WO/GA = 0.45 ensuring the maximum content of H 2 in the produced syngas according to Figure 7. Secondly, the measured wall temperature of the gasifier (=823-873 K) is seen to be 150-180 K less than the calculated equilibrium temperature of the gasification products (about 1000 K), which looks reasonable as the gasifier was not thermally insulated in the experiments.…”
Section: Modelmentioning
confidence: 94%
“…Currently, such installations for the steam gasification of organic waste, meeting specific requirements in terms of the operation temperature, the feedstock residence time, the composition of the produced syngas, etc., can be designed using computational fluid dynamics [35] and equilibrium gasification models [32,33,36]. The technology has been implemented in experimental installations and tested on a number of organic wastes, including WO [37], which is a subject of particular interest for environmentally safe utilization [38,39]. The GA generator (i.e., PDG) operates in a pulse mode, and the pulse frequency is mainly determined by the time of tube filling.…”
Section: Technologymentioning
confidence: 99%
See 2 more Smart Citations
“…The TMCG method has already been successfully demonstrated for the natural gas conversion [40] and gasification of liquid/solid wastes (waste machine oil, sawdust, sunflower seed husks, etc.) [40][41][42][43]. The objective of this paper is to demonstrate the TMCG method on the gasification of waste PCBs using a new experimental setup and accompanying measurements of gaseous and solid gasification products by the chromatography-mass spectrometry (GC-MS), CHN analysis, wet laser diffraction method, and X-ray fluorescence (XRF).…”
Section: Introductionmentioning
confidence: 99%