“…In comparison and calibration laboratories, it is recommended to use a quantity at risk less than 5% of the cases, with a false rejection probability of less than 2.5%. Based on these, we can make the following decision-making graph (Figure 3) for comparison and calibration laboratories [4]. So, we can conclude from this graph that if the measurement result is between the lower protection line and 0, the measuring tool is in compliance with the requirement, and if the measurement result is between the required accuracy limit (the upper limit of the error of the measuring tool) and the lower protection line, the measuring tool is conditionally in compliance with the requirement, the measurement result is high protection.…”
Section: Realization Of the Conceptmentioning
confidence: 99%
See 2 more Smart Citations
“…In comparison and calibration laboratories, it is recommended to use a quantity at risk less than 5% of the cases, with a false rejection probability of less than 2.5%. Based on these, we can make the following decision-making graph (Figure 3) for comparison and calibration laboratories [4]. So, we can conclude from this graph that if the measurement result is between the lower protection line and 0, the measuring tool is in compliance with the requirement, and if the measurement result is between the required accuracy limit (the upper limit of the error of the measuring tool) and the lower protection line, the measuring tool is conditionally in compliance with the requirement, the measurement result is high protection.…”
Section: Realization Of the Conceptmentioning
confidence: 99%
“…We know that currently, in the processing of comparison results, the concept of error is promoted in the countries of the Commonwealth of Independent States, according to which the permissible absolute error and relative errors of the measuring instrument are calculated, and these indicators are adjusted to the accuracy indicators specified by the manufacturer, and comparison certificates are issued. Basic absolute error value when processing comparison results according to GOST 8.618 [1][2][3][4][5] ,…”