2020
DOI: 10.1038/s41598-020-73442-0
|View full text |Cite
|
Sign up to set email alerts
|

GC–MS analysis of phytoconstituents from Amomum nilgiricum and molecular docking interactions of bioactive serverogenin acetate with target proteins

Abstract: Amomum nilgiricum is one of the plant species reported from Western Ghats of India, belonging to the family Zingiberaceae, with ethno-botanical values, and is well-known for their ethno medicinal applications. In the present investigation, ethyl acetate and methanol extracts of A. nilgiricum were analyzed by Fourier transform infrared spectrometer (FTIR) and gas chromatography-mass spectrometry (GC–MS) to identify the important functional groups and phytochemical constituents. The FTIR spectra revealed the occ… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
76
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7
2

Relationship

0
9

Authors

Journals

citations
Cited by 149 publications
(77 citation statements)
references
References 41 publications
1
76
0
Order By: Relevance
“…The phytochemical analysis of LRC was performed with an Agilent 6890 GC apparatus interfaced to an Agilent 5973 MS system equipped with an electron ionization (EI) source and autoinjector (Agilent Technologies, Inc.). GC/MS was conducted according to a previous study ( 21 ). The GC system was built with a DB-5 column (30.0 m x 0.25 mm x 0.25 µ m).…”
Section: Methodsmentioning
confidence: 99%
“…The phytochemical analysis of LRC was performed with an Agilent 6890 GC apparatus interfaced to an Agilent 5973 MS system equipped with an electron ionization (EI) source and autoinjector (Agilent Technologies, Inc.). GC/MS was conducted according to a previous study ( 21 ). The GC system was built with a DB-5 column (30.0 m x 0.25 mm x 0.25 µ m).…”
Section: Methodsmentioning
confidence: 99%
“…Detailed instrumentation is given in Supplementary Table S1. The MS phytoconstituents were identified by matching the mass spectra of the analytes with the mass spectra of standards in NIST libraries and published data [31].…”
Section: Gc/ms Analysismentioning
confidence: 99%
“…Only seven pure compounds were separated from fraction number 2 and fraction number 7. These compounds were purified, identified, and characterized by using HPLC, LS-MS, and NMR as reported by our previous studies carried by [6,7].…”
Section: Column Chromatography and Thin-layer Chromatographymentioning
confidence: 99%
“…The GC executes the separation of the compounds, whereas the MS produces the specific mass profiles of each of the detected compounds. The analysis of emissions from biogenic volatile organic compounds (VOCs) is commonly executed using GC-MS [6].…”
Section: Introductionmentioning
confidence: 99%