1997
DOI: 10.1016/s0921-4526(97)00561-9
|View full text |Cite
|
Sign up to set email alerts
|

GEM — General materials diffractometer at ISIS

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
77
0
1

Year Published

2005
2005
2017
2017

Publication Types

Select...
5
4

Relationship

0
9

Authors

Journals

citations
Cited by 103 publications
(78 citation statements)
references
References 1 publication
0
77
0
1
Order By: Relevance
“…The 7 Li 7 P 3 S 11 glass ceramics was put into a stainless seal cell with capton windows in argon gas, and a SXPD pattern was collected at RT for 2 h. We also measured a time-of-flight NPD (TOF-NPD) pattern at RT for 5 h on the General Material Diffractometer (GEM), 5,6) installed at the ISIS in the UK Rutherford Appleton Laboratory. The 7 Li 7 P 3 S 11 was put into a cylindrical vanadium can of 8 mm diameter in argon gas.…”
Section: )mentioning
confidence: 99%
“…The 7 Li 7 P 3 S 11 glass ceramics was put into a stainless seal cell with capton windows in argon gas, and a SXPD pattern was collected at RT for 2 h. We also measured a time-of-flight NPD (TOF-NPD) pattern at RT for 5 h on the General Material Diffractometer (GEM), 5,6) installed at the ISIS in the UK Rutherford Appleton Laboratory. The 7 Li 7 P 3 S 11 was put into a cylindrical vanadium can of 8 mm diameter in argon gas.…”
Section: )mentioning
confidence: 99%
“…Time-Of-Flight (TOF) neutron diffraction patterns were recorded on the high intensity, high resolution diffractometer GEM at the pulsed neutron source ISIS facility, Rutherford Appleton Laboratory, UK 25 . Due to the possibility of decomposition of the phase over a few days, a 5 g sample was stored under N2 in a sealed tube prior to measurement.…”
Section: Methodsmentioning
confidence: 99%
“…We chose to investigate such an instrument with a wavelength resolution of δλ/λ = 0.1 % and almost 4π detector coverage comparable to GEM at ISIS. 11) To obtain this high resolution a diffractometer needs to be adequately long or use a short pulse; e.g. a diffractometer using neutrons with wavelengths around 1.5 Å, 0.1 % wavelength resolution, a pulse length of 2 ms, and filling the whole time frame, will need to be more than 5 kilometres long!…”
Section: Thermal Powder Diffractometermentioning
confidence: 99%
“…It can be seen that a significant gain in intensity at the sample can be achieved by relaxing the resolution. Comparing to the GEM 11,12) instrument at ISIS that for a resolution of δd/d of ∼ 4 · 10 −3 at 115…”
Section: Sb018-mentioning
confidence: 99%