Generator Columns and High Pressure Liquid Chromatography for Determining Aqueous Solubilities and Octanol-Water Partition Coefficients of Hydrophobic Substances

Abstract: Generator columns packed with a solid support and loaded with a liquid organic phase make it possible to rapidly and conveniently equilibrate water with the organic phase. By coupling the generator column to an extractor column for high pressure liquid chromatographic analysis of the aqueous solution, errors from surface adsorption and loss to the atmosphere are avoided. Using this method, the mean values and confidence limits at a 95 percent confidence level of the aqueous solubility, S, and the octanol-water… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

4
44
0

Year Published

1981
1981
2019
2019

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 67 publications
(48 citation statements)
references
References 16 publications
4
44
0
Order By: Relevance
“…The detector response factor for each solute was evaluated by injections of a standard methanol solution of the solute into the analytical column from a sample loop, the loop volume having been determined by a spectroscopic method [3]. pendence of solubility on temperature to be determined statistically with reasonable certainty.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…The detector response factor for each solute was evaluated by injections of a standard methanol solution of the solute into the analytical column from a sample loop, the loop volume having been determined by a spectroscopic method [3]. pendence of solubility on temperature to be determined statistically with reasonable certainty.…”
Section: Resultsmentioning
confidence: 99%
“…The short section of largerdiameter tubing at the bottom of the column serves as a trap for droplets of the organic liquid pushed off the packing, preventing them from reaching the outlet tube. The organic liquid, being less dense than the aqueous solution, stays at the top of the trap; this behavior has been observed in a glass version of the generator column [3].…”
Section: Columnsmentioning
confidence: 97%
See 1 more Smart Citation
“…The enthalpy of sublimation was measured by Yanson and Teplit- E~~~. : samPlet-aaMaSS-~Olr'l:"ril.--"'Na'fllnD...HM----' _IR~: ., ... Miller and Wasik [23] measured the solubility of our crystalline guanine sample, Gua 1, at three temperatures using a liquid chromatographic method developed by Wasik which is described elsewhere [24]. The guanine was first dissolved in methanol as a carrier liquid and transferred to the chromatographic column.…”
Section: Discussion and Summarymentioning
confidence: 99%
“…A direct method to measure Kow values of very hydrophobic compounds has been developed by using the generator column technique, which avoids problems such as colloidal suspension, absorption, and volatilization of the solute Miller et al, 1984;De Voe et al, 1981). With this technique an noctanol solution of the compound is sorbed to a solid support in a column.…”
Section: Introductionmentioning
confidence: 99%