2010
DOI: 10.1007/s00506-010-0185-2
|View full text |Cite
|
Sign up to set email alerts
|

GEO-Pot: Seichtes Geothermie Potenzial Österreichs. Überregionale, interdisziplinäre Potenzialstudie zur Erhebung und Darstellung des oberflächennahen geothermischen Anwendungspotenzials auf Grundlage eines regelmäßigen Bearbeitungsrasters

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
4
0
2

Year Published

2011
2011
2020
2020

Publication Types

Select...
4
1

Relationship

0
5

Authors

Journals

citations
Cited by 6 publications
(6 citation statements)
references
References 1 publication
0
4
0
2
Order By: Relevance
“…The standard length for a BHE varies for each country. For example, in the UK, the typical length is 150 m (Zhang et al 2014) or in Austria 110 m (Götzl et al 2010). In Germany, BHEs typically have a length of up to 100 m, since deeper BHEs require special licensing according to the German federal mining law (BBergG 1980).…”
Section: Vertical Ground Source Heat Pump (Vgshp) Systemsmentioning
confidence: 99%
See 3 more Smart Citations
“…The standard length for a BHE varies for each country. For example, in the UK, the typical length is 150 m (Zhang et al 2014) or in Austria 110 m (Götzl et al 2010). In Germany, BHEs typically have a length of up to 100 m, since deeper BHEs require special licensing according to the German federal mining law (BBergG 1980).…”
Section: Vertical Ground Source Heat Pump (Vgshp) Systemsmentioning
confidence: 99%
“…For example, Zhu et al (2010) and Zhang et al (2014) computed the theoretical geothermal potential as the heat content stored in a given volume of the subsurface for a given temperature reduction. According to Götzl et al (2010), the potential of shallow geothermal energy is a combination of the technical potential, i.e., the energetic supply, and the applicability on part of energy consumers. A similar definition was given by Zhang et al (2014) and Galgaro et al (2015), who defined a ratio of the maximum amount of energy exchanged between the ground and vGSHP system to the heat or cooling demand.…”
Section: Introductionmentioning
confidence: 99%
See 2 more Smart Citations
“…Speicherkapazität, Dichte und Wärmeleitung des Erdreichs bewirken maßgebliche Unterschiede in den Ergebnissen, werden aber üblicherweise in geotechnischen Gutachten nicht näher untersucht. Für das gegenständliche Objekt wurde daher die Geologische Bundesanstalt hinzugezogen, um aus den allgemeinen geologischen Verhältnissen im Großraum des Bauplatzes [10] und den Aussagen des geologischen Gutachtens zu Schichtaufbau, Bodenarten und Grundwasserführung konkrete Annahmen für die Erdreichparameter treffen zu können. Diese wurden in weiterer Folge mit einer Sensitivitätsanalyse untersucht, um im möglichen Schwankungsbereich den Worst Case zu eruieren und diesen als Randbedingung festzulegen.…”
Section: Erdreichmodellunclassified