2015
DOI: 10.1016/j.ijrobp.2015.02.053
|View full text |Cite
|
Sign up to set email alerts
|

Geometric Verification of Dynamic Wave Arc Delivery With the Vero System Using Orthogonal X-ray Fluoroscopic Imaging

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
10
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
7

Relationship

3
4

Authors

Journals

citations
Cited by 13 publications
(11 citation statements)
references
References 25 publications
1
10
0
Order By: Relevance
“…Although additional immobilization is unlikely to be necessary for intracranial treatments, this may be a significant issue for other body sites and requires investigation. An alternative linac configuration capable of rotation around the vertical axis allows non-coplanar treatment without patient movement and would address some of these problems [32,33]. However, the reduced range of rotation achievable [32] may limit the utility of this approach for intracranial sites.…”
Section: Region Of Interest/metricmentioning
confidence: 99%
“…Although additional immobilization is unlikely to be necessary for intracranial treatments, this may be a significant issue for other body sites and requires investigation. An alternative linac configuration capable of rotation around the vertical axis allows non-coplanar treatment without patient movement and would address some of these problems [32,33]. However, the reduced range of rotation achievable [32] may limit the utility of this approach for intracranial sites.…”
Section: Region Of Interest/metricmentioning
confidence: 99%
“…The concept of DWA was developed as "unicursal irradiation" 3 and the geometric verification and quality assurances were subsequently confirmed. 4,5 DWA allows sequential noncoplanar beams to be safely and quickly used without rotating the couch. DWA can be realized with intensity modulated beams, and a new radiation technique that combines DWA with intensity modulation has been developed: volumetric-modulated Dynamic WaveArc therapy (VMDWAT).…”
Section: Introductionmentioning
confidence: 99%
“…Re-verification of the patient setup after or during rotation of the couch is therefore currently required in clinical routine [ 22 , 23 ]. The Wave Arc planning module allows one to design individualized patient treatments, while the Vero’s hardware controller ensures a continuous reliable delivery [ 8 , 9 ]. No additional patient immobilization is required other than that already employed in clinical routine, since the O-ring design allows two-dimensional movements without any couch maneuvering.…”
Section: Discussionmentioning
confidence: 99%
“…The speed of the gantry and ring can be accurately modulated due to the rigid gear transmission design, which allows the system to preserve its rigidity even during complex gantry-ring movements. The theoretical concept of DWA was presented by Mizowaki et al [ 7 ] under the term “3D unicursal irradiation” and the technique was subject to other more technically orientated reports regarding geometrical and dosimetric accuracy [ 8 , 9 ].…”
Section: Introductionmentioning
confidence: 99%