2001
DOI: 10.1107/s0909049501006422
|View full text |Cite
|
Sign up to set email alerts
|

Geometrical fitting of experimental XANES spectra by a full multiple-scattering procedure

Abstract: In this paper a new software procedure is presented, named MXAN, able to fit the XANES part (from the edge to about 200 eV) of experimental X-ray absorption data. The method is based on the fitting between the experimental spectrum and several theoretical calculations generated by changing the relevant geometrical parameters of the site around the absorbing atom. The X-ray photoabsorption cross section is calculated using the full multiplescattering scheme; different choices of the exchange correlation part of… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
206
0

Year Published

2010
2010
2016
2016

Publication Types

Select...
4
2
1

Relationship

0
7

Authors

Journals

citations
Cited by 195 publications
(206 citation statements)
references
References 22 publications
0
206
0
Order By: Relevance
“…Experimental XAS spectra were theoretically modeled using MXAN, which performs full multiple scattering analysis to obtain structural information [8], [9]. Starting structures were taken from the best three-dimesional models that included the coordination numbers 4, 6, 8, and 10 with radial metrics obtained from EXAFS analysis.…”
Section: Discussionmentioning
confidence: 99%
See 2 more Smart Citations
“…Experimental XAS spectra were theoretically modeled using MXAN, which performs full multiple scattering analysis to obtain structural information [8], [9]. Starting structures were taken from the best three-dimesional models that included the coordination numbers 4, 6, 8, and 10 with radial metrics obtained from EXAFS analysis.…”
Section: Discussionmentioning
confidence: 99%
“…EXAFS fits were used to test structural models (4,6,8, and 10 coordinate geometries), which were subsequently used to fit the near-edge data. MXAN has the advantage that it mostly independent of thermal noise/Debye-Waller factors, which lead to EXAFS signal dampening and broadening.…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation
“…Recent theoretical advances have made the extended X-ray absorption fine structure (EXAFS) analysis a primary, well established structural tool to investigate bond lengths at a precision of about 0.02 Å [9]. Moreover, a quantitative X-ray absorption near edge structure (XANES) analysis has been developed [10,11] and applied in combination with EXAFS to different system to extract information on bond distances and angular…”
Section: Accepted Manuscriptmentioning
confidence: 99%
“…The XANES calculations have been performed using the MXAN software procedure [8,10]. The analysis of the XANES spectra has been carried out using a cluster of thirty-one atoms, i.e., the porphyrin macrocycle, the histidine imidazole, and the oxygen of an unbound water molecule.…”
Section: Quantitative Xanes Analysismentioning