2018
DOI: 10.1007/s40808-018-0455-8
|View full text |Cite
|
Sign up to set email alerts
|

Geophysical and hydro-chemical investigation of contamination plume in a basement complex formation around Sunmoye dumpsite in Ikire, Southwestern Nigeria

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5

Relationship

1
4

Authors

Journals

citations
Cited by 9 publications
(3 citation statements)
references
References 7 publications
0
3
0
Order By: Relevance
“…The locality of the chosen wells was determined using the global positioning system (GPS) receiver. Two liter plastic containers were used for the sample collection, prior to the sample collection, the plastic containers were thoroughly washed with 1 M HCl, and afterward flushed multiple times with the inspected water at the site before the water tests were collected (Akinola et al 2018). The pH and portable digital conductivity meters were used in-situ to determine the physical properties [pH, temperature and electrical conductivity (EC)] of the groundwater.…”
Section: Methods Of Sample Collection and Analysismentioning
confidence: 99%
See 1 more Smart Citation
“…The locality of the chosen wells was determined using the global positioning system (GPS) receiver. Two liter plastic containers were used for the sample collection, prior to the sample collection, the plastic containers were thoroughly washed with 1 M HCl, and afterward flushed multiple times with the inspected water at the site before the water tests were collected (Akinola et al 2018). The pH and portable digital conductivity meters were used in-situ to determine the physical properties [pH, temperature and electrical conductivity (EC)] of the groundwater.…”
Section: Methods Of Sample Collection and Analysismentioning
confidence: 99%
“…The mean annual rainfall is between 1000 and 1400 mm while the monthly average temperatures range between 21 °C and 30 °C. For a quite long time, part of the city faces problems related to untreated waste disposal and pollution (Akinola et al 2018). Geologically, the investigated area is underlain by the Precambrian Basement Complex Rocks of southwestern Nigeria (Rahaman 1976).…”
Section: Description Of the Study Areamentioning
confidence: 99%
“…The measurements of the electrical resistivity could in turn be used to determine the true resistivity of the subsurface. The DC resistivity techniques have been used over the years in groundwater exploration (Gautam and Biswas 2016;Oyeyemi et al 2018a, b), engineering investigations (Oladunjoye et al 2017;Oyeyemi et al 2017Oyeyemi et al , 2020, mineral exploration (Zhang et al 2015;Sanuade et al 2018), and environmental studies (Rosales et al 2012;Akinola et al 2018;Olaojo et al 2018;Olaseeni et al 2018). However, to obtain the electrical resistivity image that would be a representation of the subsurface, the electric potential data that are measured on the field must be inverted, and forward modeling is an important step for any inversion algorithms to be used (Gao et al 2020).…”
Section: Introductionmentioning
confidence: 99%