Glass Fiber versus Carbon Fiber Grid used in Textile Reinforced Mortar Strengthening of Precast RC Walls

Abstract: The experimental study presented hereis based on the seismic performance investigation of precast reinforced concrete wall panels (PRCWP), post-damage strengthening using different materials and different anchorage systems. Both wall panels have an initial small window opening, but the second panel has the opening enlarged into a large window opening in order to investigate also the cutout effect. The behavior and failure details are presented and analyzed for both unstrengthened and post-damage strengthened s… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2015
2015
2015
2015

Publication Types

Select...
1

Relationship

1
0

Authors

Journals

citations
Cited by 1 publication
(2 citation statements)
references
References 3 publications
0
2
0
Order By: Relevance
“…The specimen outlines and reinforcement details are presented in Todut et al [27,28]. The strengthened elements were renamed using a specific notation: the suffix T/R refers to elements initially tested prior to failure, thereafter retrofitted and retested; R/T for elements retrofitted initially on undamaged elements and tested; and the reference elements tested initially have the suffix (T).…”
Section: Experimental Specimens and Test Setupmentioning
confidence: 99%
See 1 more Smart Citation
“…The specimen outlines and reinforcement details are presented in Todut et al [27,28]. The strengthened elements were renamed using a specific notation: the suffix T/R refers to elements initially tested prior to failure, thereafter retrofitted and retested; R/T for elements retrofitted initially on undamaged elements and tested; and the reference elements tested initially have the suffix (T).…”
Section: Experimental Specimens and Test Setupmentioning
confidence: 99%
“…The first layer of the TRM component mortar (Sika Monotop 722 Mur) was then applied, followed by the glass fibre grid (SikaWrap 350G) fixed with a nut and washer and the second layer of mortar. Detailed data related to the glass fibre grid application are presented in Todut et al [28]. The strengthening solution was applied symmetrically on both faces of the wall (Fig.…”
Section: Rehabilitation Of Prcwp (10-l1/l3-t/r) Using Trmmentioning