1973
DOI: 10.1002/jps.2600620510
|View full text |Cite
|
Sign up to set email alerts
|

GLC Determination of Nitroglycerin and Isosorbide Dinitrate in Human Plasma

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
17
0

Year Published

1977
1977
1987
1987

Publication Types

Select...
10

Relationship

0
10

Authors

Journals

citations
Cited by 95 publications
(17 citation statements)
references
References 10 publications
0
17
0
Order By: Relevance
“…Each specimen was collected in an anticoagulant tube, quickly centrifuged and the plasma decanted and quick-frozen. The technique of gas-liquid chromatography with electroncapture detection, as described by Rosseel & Bogaert (1973) Figure 1 shows in graphic form the plasma concentrations of ISDN, 2-ISMN and 5-ISMN in a patient (T.T. ), whose daily dose of ISDN was 360 mg.…”
Section: Methodsmentioning
confidence: 99%
“…Each specimen was collected in an anticoagulant tube, quickly centrifuged and the plasma decanted and quick-frozen. The technique of gas-liquid chromatography with electroncapture detection, as described by Rosseel & Bogaert (1973) Figure 1 shows in graphic form the plasma concentrations of ISDN, 2-ISMN and 5-ISMN in a patient (T.T. ), whose daily dose of ISDN was 360 mg.…”
Section: Methodsmentioning
confidence: 99%
“…Therefore, it is of great interest to measure plasma levels of all three compounds together, but only few methods have been yet described In five procedures, conventional pack.ed column GLC was used, however, neither of these assays led to satisfactory sensitivity and selectivity. Large sample volumes (3-5 ml) are required [8,11,12] and difficulties occurred with the [8-141. quantitative mononitrate determination due to peak interferences, mainly by IS-5-MN [l 11. In two assays no internal standard was used [10,11].…”
Section: Introductionmentioning
confidence: 99%
“…Supernatant plasma (3 ,ul) was transferred to a 10 ml capacity glass tube and 10 ,ul of 25 ng/ml y-lindane in hexane were added to each sample as internal standard. Hexane was used instead of ethylacetate as previously described (Rosseel & Bogaert, 1973) because it is more easily purified and was found to extract fewer unwanted plasma constituents. y-lindane was used instead of isosorbide dinitrate as previously described (Rosseel & Bogaert, 1973;Yap et al, 1978;Armstrong et al, 1979) because it is more soluble in hexane and has a shorter retention time.…”
Section: Protocolmentioning
confidence: 99%