2021
DOI: 10.1177/1932296821997179
|View full text |Cite
|
Sign up to set email alerts
|

Glycated Hemoglobin Measurement: Comparison of Three Methods Versus High Performance Liquid Chromatography

Abstract: Background: HbA1c result provide information on metabolic control in diabetes mellitus (DM) and could also be used for its diagnosis. For its determination, the laboratory must be certified by the National Glycohemoglobin Standardization Program (NGSP) or the International Federation of Clinical Chemistry (IFCC) and comply with a strict quality control program. Aims: To determine the correlation and agreement between HbA1c results measured by three analytical methods (enzymatic, turbidimetric, and capillary el… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

0
6
0
1

Year Published

2021
2021
2024
2024

Publication Types

Select...
6
1

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(7 citation statements)
references
References 15 publications
0
6
0
1
Order By: Relevance
“…Ryman spectroscopy analysis method: the structure is relatively complex, and it is not easy to be accepted by patients [24]. Ion chromatography analysis method: its sensitivity, stability and accuracy are poor, and this method is susceptible to interference from other substances in saliva, which affects the detection results [25]. The ultra-micro ultraviolet spectrophotometer method in this study is a highly repeatable method with high sensitivity and high detection accuracy.…”
Section: Discussionmentioning
confidence: 94%
“…Ryman spectroscopy analysis method: the structure is relatively complex, and it is not easy to be accepted by patients [24]. Ion chromatography analysis method: its sensitivity, stability and accuracy are poor, and this method is susceptible to interference from other substances in saliva, which affects the detection results [25]. The ultra-micro ultraviolet spectrophotometer method in this study is a highly repeatable method with high sensitivity and high detection accuracy.…”
Section: Discussionmentioning
confidence: 94%
“…Como se mencionó anteriormente, durante las Quintas Jornadas Rioplatenses se estableció en 110 mg/dL el nivel a partir del cual se debería considerar GAA y además, debido a la falta de estandarización del método en la región, se recomendó no utilizar la HbA1c como método de diagnóstico 1 , indicación que posiblemente hoy debería revisarse porque existe evidencia recientemente publicada en conjunto por la SAD y la ALAC en relación a que, al menos en Argentina, se cuenta con laboratorios que utilizan métodos certificados para la medición de HbA1c que podrían brindar resultados confiables a tal efecto 9 .…”
Section: Discussionunclassified
“…Hypertension was defined as systolic blood pressure ≥140 mmHg, diastolic blood pressure ≥90 mmHg, or taking hypertension medications 10 . Diabetes was diagnosed when HbA1c was ³6.5% or using diabetes medications 11 . Dyslipidemia was established if the participant was using hypolipidemic medication or if at least one of the following criteria was met: reduced high-density lipoprotein cholesterol, a level <40 mg/dL in men or 50 mg/dL in women; hypertriglyceridemia, a triglyceride level >150 mg/dL; and hypercholesterolemia, an low-density lipoprotein cholesterol >160 mg/dL 12 .…”
Section: Clinical Parameters and Laboratory Testingmentioning
confidence: 99%