2019
DOI: 10.1016/j.snb.2019.03.096
|View full text |Cite
|
Sign up to set email alerts
|

Glycoconjugates coated gold nanorods based novel biosensor for optical detection and photothermal ablation of food borne bacteria

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
26
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6
1
1

Relationship

0
8

Authors

Journals

citations
Cited by 43 publications
(26 citation statements)
references
References 38 publications
0
26
0
Order By: Relevance
“…Figure 19 depicts the structure of compounds used to introduce carboxyl groups on AuNR. A characteristic that have in common is to include a terminal thiol function to create strong Au-S bonds and a carboxylic acid function at the other end, typically MUA [ 20 , 156 , 157 , 158 , 159 ], MHDA [ 160 , 161 ], or mercaptoPEG acid derivatives [ 162 , 163 , 164 , 165 , 166 , 167 ]. This general strategy has been applied to decorate AuNR with bioreceptors both in solution or once deposited on solid substrates (essentially glass slides) using the mercaptocarboxylic acids alone or in mixture with other thiols like mPEG-SH or 11-mercaptoundecanol in various proportions.…”
Section: Functionalization Methods Of Gold Nanorodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Figure 19 depicts the structure of compounds used to introduce carboxyl groups on AuNR. A characteristic that have in common is to include a terminal thiol function to create strong Au-S bonds and a carboxylic acid function at the other end, typically MUA [ 20 , 156 , 157 , 158 , 159 ], MHDA [ 160 , 161 ], or mercaptoPEG acid derivatives [ 162 , 163 , 164 , 165 , 166 , 167 ]. This general strategy has been applied to decorate AuNR with bioreceptors both in solution or once deposited on solid substrates (essentially glass slides) using the mercaptocarboxylic acids alone or in mixture with other thiols like mPEG-SH or 11-mercaptoundecanol in various proportions.…”
Section: Functionalization Methods Of Gold Nanorodsmentioning
confidence: 99%
“…Although antibodies and aptamers are the most commonly used bioreceptors for AuNR-LSPR biosensors, several less common biomolecules were also employed as summarized in Table 7 . AuNR-based biosensors using sugar bioreceptors were developed to assay food allergens [ 162 ] or the cancer biomarker galectin-1 [ 145 ]. AuNR-based genosensors were reported for the detection of pathogens [ 141 , 143 ].…”
Section: Applications Of Aunrs In Lspr Biosensingmentioning
confidence: 99%
“…Proteins on the bacterial surface are able to bind to different types of glycans on the host cells. Kaushal et al focused on a rapid detection of the food–borne pathogen E. coli with the application of gold nanorods-based sensors with good near-infrared absorption and scattering in surface plasmon resonance wavelength regions [ 91 ]. Polyethylene glycol-coated Au nanorods were immobilized by amine-terminated sugars—4-aminophenyl α-D-mannopyranoside and 4-aminophenyl β-D-galactopyranoside.…”
Section: Glycan-functionalized Nanoparticles (Nps)mentioning
confidence: 99%
“…E. coli bacteria bind to mannose-modified AuNPs and Pseudomonas aeruginosa was used as a control to check the aggregation of the galactose-modified nanorods. The assay was performed in a 96-well plate for a visible colorimetric detection [ 91 ].…”
Section: Glycan-functionalized Nanoparticles (Nps)mentioning
confidence: 99%
“…However, the requirement for pre-enrichment in non-selective culture broth, selective enrichment and plating, biochemical analysis and serological confirmation makes these methods labour-intensive and time-consuming, as the entire process can take several days [13,14]. In recent years, many efforts have been directed toward the development of new methods or techniques including immuno-based assays [15,16], polymerase chain reaction (PCR) [17], surface plasmon resonance (SPR) [18], flow cytometry (FC) [19] and loop-mediated isothermal amplification (LAMP) [20,21,22]. However, these methods entail multiple processing steps, hence increasing the risk of cross-contamination.…”
Section: Introductionmentioning
confidence: 99%