1984
DOI: 10.1016/s0140-6736(84)92705-3
|View full text |Cite
|
Sign up to set email alerts
|

Glycosylation and Uraemia

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

1985
1985
2013
2013

Publication Types

Select...
4

Relationship

0
4

Authors

Journals

citations
Cited by 4 publications
(3 citation statements)
references
References 3 publications
0
3
0
Order By: Relevance
“…Presumably, hemoglobin species modified by reactants other than glucose and not displaying a cis-1,1-diol group should not interfere with measurement of HbA 1c by boronate affinity methods. Published data support this lack of interference of carbHb with boronate affinity methods [6,16,17]. Therefore, we used the boronate affinity ultra 2 HPLC (Trinity Biotech) as our comparative method.…”
Section: Methodsmentioning
confidence: 94%
See 1 more Smart Citation
“…Presumably, hemoglobin species modified by reactants other than glucose and not displaying a cis-1,1-diol group should not interfere with measurement of HbA 1c by boronate affinity methods. Published data support this lack of interference of carbHb with boronate affinity methods [6,16,17]. Therefore, we used the boronate affinity ultra 2 HPLC (Trinity Biotech) as our comparative method.…”
Section: Methodsmentioning
confidence: 94%
“…We therefore used eGFR as an indicator of overall renal function in place of direct measurement of carb Hb. We used a boronate affinity chromatography HPLC method as our reference method since this method has been shown to have no interference from carbHb [6,7,16,17]. …”
Section: Introductionmentioning
confidence: 99%
“…Some of them found normal glycosylation values in uremic patients when using the TBA or affinity-chromatographic meth ods [19,25,31,33,34], but others like Haley and Ward [35] reported elevated levels of PGP determined with the TBA assay in hemodialysis and continuous peritoneal dialysis patients, while Bannon et al [36] also found 22% high GHb levels determined with the affinity chro matography method in hemodialysis patients and a dif ference in the GHb variances as compared with the nor mal group. These discrepancies are probably based on methodological differences: most works include few pa tients on conservative treatment, the range of renal func tion varies considerably among them, there are differ ences in the degree of anemia and blood transfusions received.…”
Section: Discussionmentioning
confidence: 99%