2013
DOI: 10.1039/c3ra42684j
|View full text |Cite
|
Sign up to set email alerts
|

Gold dissolution: towards understanding of noble metal corrosion

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

18
188
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 161 publications
(206 citation statements)
references
References 66 publications
18
188
0
Order By: Relevance
“…Formation and reduction of gold and platinum oxides in acidic and alkaline electrolytes.-It has been established that electrochemical dissolution of gold 63,64 and platinum 65,66 in acidic media takes place at potentials at which the metal surface is, at least partially, oxidized. Independent of the pH, in 0.01, 0.1 and 1 M sulfuric acid electrolytes, the onset of gold dissolution occurred at ca.…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…Formation and reduction of gold and platinum oxides in acidic and alkaline electrolytes.-It has been established that electrochemical dissolution of gold 63,64 and platinum 65,66 in acidic media takes place at potentials at which the metal surface is, at least partially, oxidized. Independent of the pH, in 0.01, 0.1 and 1 M sulfuric acid electrolytes, the onset of gold dissolution occurred at ca.…”
Section: Resultsmentioning
confidence: 99%
“…31,62,64,66 Merck Suprapur 96% H 2 SO 4 and 70% HClO 4 were diluted using ultrapure water (PureLab Plus system, Elga, 18 M , TOC < 3 p.p.b.) for preparation of 0.1 M acidic electrolytes.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Since gold is not expected to be stable at high oxidative potentials, [40] we did not perform reference measurements with the bare EQCM crystals. Instead, the gold was coated by the catalyst thin film, as described above, and we measured the amount of gold in the electrolyte after OER tests.…”
Section: Electrochemical Testsmentioning
confidence: 99%
“…On the other hand, macroscopic techniques can be applied to determine the corrosion rates; these include the rotating ring disk electrode (RRDE; for example, for monitoring the anodic dissolution of RuO 2 [36,37] ), the quartz crystal microbalance, [38] and inductively coupled plasma mass spectrometry (ICP-MS). [39][40][41] Nonetheless, as of yet, no standardized protocols for assessing the stability under OER conditions have emerged.…”
Section: Introductionmentioning
confidence: 99%