2017
DOI: 10.2166/hydro.2017.225
|View full text |Cite
|
Sign up to set email alerts
|

GoRoSoBo: an overall control diagram to improve the efficiency of water transport systems in real time

Abstract: Abstract:The agriculture holds an important part of the food chain and the water resources for agriculture are essential. The problem is the water transport systems present low efficiencies in practice. The yield agriculture has to be optimized, because the goal of an operational water manager is to deliver the water to the irrigation sites accurately and efficiently. In order to fulfill this objective, we propose a centralized overall control diagram to optimize the management of the canal. Our control diagra… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
5
1

Relationship

3
3

Authors

Journals

citations
Cited by 7 publications
(7 citation statements)
references
References 15 publications
0
7
0
Order By: Relevance
“…Therefore, in order to obtain a stable control-oriented model, the obtained model has a high order. this modeling strategy is used in several reported works (e.g., Reddy 1990b;Garcia et al 1992;Mohan Reddy et al 1992;Mohan Reddy 1995;Reddy 1996;Mohan Reddy and Jacquot 1999;Durdu 2004Durdu , 2006Lemos et al 2009;Durdu 2010;Feng and Wang 2011;Shang et al 2011;Xu et al 2012;Breckpot et al 2013;Soler et al 2013a;Cen et al 2017;Bonet et al 2017;Lacasta et al 2018). On the other hand, Malaterre (1998) uses an implicit Preissmann finite-difference scheme, with the advantage that the stability of the model does not depend on the discretization step size, and Liu et al (1998) propose the use of this scheme in the development of a control strategy based on an inverse solution of the nonlinear SVE.…”
Section: Models Obtained From Simplifications Of the Svementioning
confidence: 99%
See 2 more Smart Citations
“…Therefore, in order to obtain a stable control-oriented model, the obtained model has a high order. this modeling strategy is used in several reported works (e.g., Reddy 1990b;Garcia et al 1992;Mohan Reddy et al 1992;Mohan Reddy 1995;Reddy 1996;Mohan Reddy and Jacquot 1999;Durdu 2004Durdu , 2006Lemos et al 2009;Durdu 2010;Feng and Wang 2011;Shang et al 2011;Xu et al 2012;Breckpot et al 2013;Soler et al 2013a;Cen et al 2017;Bonet et al 2017;Lacasta et al 2018). On the other hand, Malaterre (1998) uses an implicit Preissmann finite-difference scheme, with the advantage that the stability of the model does not depend on the discretization step size, and Liu et al (1998) propose the use of this scheme in the development of a control strategy based on an inverse solution of the nonlinear SVE.…”
Section: Models Obtained From Simplifications Of the Svementioning
confidence: 99%
“…] ⊤ ∈ ℝ is considered as a desired level vector, and ̄ is the mean of because excessive gates and flows changes produce mechanical wear and water levels oscillations, to reduce excessive gates and flows changes is desired. The key performance indicators can be used as a measure of performance for controlled systems (e.g., Xu et al 2012;Munir et al 2012;Soler et al 2013a;Bonet et al 2017;Ke et al 2018;Zheng et al 2019), and as a design criteria in optimal controllers (e.g., Feliu-Batlle et al 2011;Ke et al 2018). A relation of the principal key performance indicators is presented in Table 3, where: i) the maximum absolute error (MAE) is the maximum normalized error between the desired and measured level; ii) the integral of the absolute error (IAE) accounts for the cumulative level error along a time period ( ); iii) the steady-state error (StE) is the maximum absolute level error during a time period when the steady state has been reached; iv) the integral square error (ISE) also accounts for the cumulative level error and weights large deviations; v) the absolute gate movement (IAW) relates to positions changes of the regulation structures; and vi) the integrated absolute discharge change (IAQ) accounts for flow variations.…”
Section: Tablementioning
confidence: 99%
See 1 more Smart Citation
“…In this scenario, the appropriate conservation of water infrastructures is essential for the management of water resources for both the present and future generations. In addition to these considerations, water resources are expected to decrease as a result of climate change (Bonet et al, 2017). Urban water systems constitute a vital segment of the global public infrastructure for water utilities, and the municipalities are tasked with the responsibility of overseeing and improving them for present and future generations.…”
Section: Introductionmentioning
confidence: 99%
“…As shown in Figure 2, the primary energy sources in Spain were oil and natural gas, with 39.6% and 21% shares of the market in 2017, respectively. These were usually used to generate electricity according to International Energy Agency [6]. On the other hand, by 2021, wind energy had become the increasingly leading source of renewable energy.…”
Section: Introductionmentioning
confidence: 99%