2022
DOI: 10.1007/s00348-022-03444-3
|View full text |Cite
|
Sign up to set email alerts
|

GPU-accelerated MART and concurrent cross-correlation for tomographic PIV

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2022
2022
2024
2024

Publication Types

Select...
7
2

Relationship

3
6

Authors

Journals

citations
Cited by 16 publications
(9 citation statements)
references
References 45 publications
0
9
0
Order By: Relevance
“…Figure 15 shows the Eulerian flow field with iso-surfaces of Q = 0.5 U 0 2 /D e 2 colored by streamwise velocity. For comparison, the Tomo-PIV result in figure 15(a) is reconstructed using a custom GPU-based Tomo-PIV framework [51]. Notably, the flow-field noise is large, and the non-zero divergence of velocity is significant (most absolute values greater than 0.11 U 0 2 /D e 2 ) in the Tomo-PIV data.…”
Section: Resultsmentioning
confidence: 99%
“…Figure 15 shows the Eulerian flow field with iso-surfaces of Q = 0.5 U 0 2 /D e 2 colored by streamwise velocity. For comparison, the Tomo-PIV result in figure 15(a) is reconstructed using a custom GPU-based Tomo-PIV framework [51]. Notably, the flow-field noise is large, and the non-zero divergence of velocity is significant (most absolute values greater than 0.11 U 0 2 /D e 2 ) in the Tomo-PIV data.…”
Section: Resultsmentioning
confidence: 99%
“…As shown in Fig. 1(a), a tall octagonal tank (with sides of 250 mm and a height of 900 mm) filled with tap water was designed to investigate the dynamical behavior of 3D jet flows at various Re and visualize 3D jet flows , He et al 2021, He et al 2022. Owing to this design and its deformable nozzle outlets, jet experiments at different AR values were conducted in this octagonal tank.…”
Section: Methodsmentioning
confidence: 99%
“…1, a measurement area of 50 mm (2.5D in the x-direction)  100 mm (5D in the y-direction)  50 mm (2.5D in the z-direction) was reconstructed with a discretization of 11 voxels/mm to obtain the particle field. The velocity vectors were efficiently calculated from the raw particle volumes using a graphics processing unit-based Tomo-PIV framework developed in-house (Zeng et al 2022). The interrogation volume was set in turn to 64 3 and 32 3 voxels with a 50% overlap, which realized a resolution of 14 vectors per D. The measurement of the circular nozzle was repeated three times with 6,320 image sets each time, which yielded 9,960 frames of 3D flow field snapshots.…”
Section: Methodsmentioning
confidence: 99%
“…The particle displacement in the mainstream for each pair of images is approximately 4 pixels according to the imaging time interval. GPU-accelerated code (Zeng, He & Liu 2022) based on the MART algorithm, combined with the iterative multigrid volumetric cross-correlation approach with a final pass interrogation volume size of 32 × 32 × 32 voxels and 50 % overlap, is used to determine the three-dimensional velocity fields. This yields a spatial resolution of the velocity vectors of 1.2 mm.…”
Section: Computational and Synthesis Tomo-piv Set-upsmentioning
confidence: 99%