1982
DOI: 10.1016/s0003-2670(01)95368-1
|View full text |Cite
|
Sign up to set email alerts
|

Gradient techniques in flow injection analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
23
0
6

Year Published

1984
1984
2023
2023

Publication Types

Select...
4
3

Relationship

0
7

Authors

Journals

citations
Cited by 105 publications
(29 citation statements)
references
References 9 publications
0
23
0
6
Order By: Relevance
“…This situation is possibly covered better by the "one-tank" model but examination of their experimental results shows the rise time to occupy a significant proportion of the total peak time, at variance with the prediction of an infinitely fast rise time. This paper [6] also corrects an error in the equivalence condition made in the earlier paper [2], but perpetuates the hidden approximation in deriving the equation for the single-line mani fold.…”
mentioning
confidence: 55%
See 3 more Smart Citations
“…This situation is possibly covered better by the "one-tank" model but examination of their experimental results shows the rise time to occupy a significant proportion of the total peak time, at variance with the prediction of an infinitely fast rise time. This paper [6] also corrects an error in the equivalence condition made in the earlier paper [2], but perpetuates the hidden approximation in deriving the equation for the single-line mani fold.…”
mentioning
confidence: 55%
“…It is proposed here that all methods encompassed by the terminology above be known as "peak width" methods and that these form a subset of all "time-based" methods in f.i.a. This latter set would also include methods based on "electronic dilu tion" [6], "gradient calibration" (both decreasing [6] and increasing [7] ), "stopped flow" [8], "gradient scanning" [9] and "zone sampling" [10] amongst others.…”
mentioning
confidence: 99%
See 2 more Smart Citations
“…FI [6,7] and boron in plants [8], and to the simultaneous determinations of magnesium and calcium [9]. This technique, in combination with the merging zones principle [5] [5] and urea [11], ethanol in blood and spirits [12], glycerol and triglycerides [13], and the activity of the enzymes galactic dehydrogenase [10], alkaline phosphatase, lipase, acetylcholinesterase and chymothripsin in plasma and serum [14], have been determined. FI-SF in conjunction with catalytic reactions has been used in the determination of various ions, such as Co(II) [15], cyanide [16], Cu(II) in foodstuffs [17], and Cu(II) and Hg(II) simultaneously [18].…”
Section: Introductionmentioning
confidence: 99%