Purpose:
The purpose of this study was to present a new surgical technique to convert a single roll of Descemet membrane (DM) into a double roll using 2 cannulas in a balanced salt solution–filled Petri dish during DM endothelial keratoplasty.
Methods:
A single DM roll stained with trypan blue was placed in a balanced salt solution–filled Petri dish. Two cannulas (28G) were introduced from opposite ends of the single roll, inserted into the roll, and slowly spread apart to change the single roll into a double roll. The DM was aspirated into the modified Jones tube and loaded, maintaining a double-roll configuration with endothelium-down orientation in a bevel-up position. The modified Jones tube with the bevel down was inserted into the recipient anterior chamber through the main wound. The modified Jones tube was rotated to the bevel-up orientation. After checking the graft orientation, the DM was inserted into the recipient anterior chamber. The double-roll DM was easily unfolded by tapping the center of the cornea using a cannula. A 28G cannula was inserted under the DM, and the anterior chamber was filled with air.
Results:
Three months after surgery, the patient's corrected visual acuity in the right eye was 6/7.5 and the endothelial cell count was 1095/mm2. The corneal thickness was 533 μm, and the cornea was clear.
Conclusions:
The double-cannula maneuver mechanically changes the single roll of the donor DM to a double roll outside the recipient anterior chamber, making DM unfolding easier and minimizing the risk of upside-down apposition of the donor DM.