Grafted mesoporous silicas for radionuclide uptake: Radiolytic stability under electron irradiation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

2
2
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
3
1

Relationship

1
3

Authors

Journals

citations
Cited by 4 publications
(4 citation statements)
references
References 62 publications
2
2
0
Order By: Relevance
“…Obviously, it is higher than the yield measured in SBA-15 (0.08 ± 0.01 µmol.J -1 ), and also higher than the value measured in bulk water (0.045 ± 0.04 µmol.J -1 ) (Spinks,Woods, 1990). The H 2 radiolytic yield measured in the grafted sample is consistent, although higher, with measurements performed on other grafted SBA-15 samples (Zante et al, 2022). In this latter case, the major gas produced under irradiation was CO (and not H 2 ) due to the preferential radiolysis of the amide functional group.…”
Section: Gas Production Under Irradiationsupporting
confidence: 84%
See 2 more Smart Citations
“…Obviously, it is higher than the yield measured in SBA-15 (0.08 ± 0.01 µmol.J -1 ), and also higher than the value measured in bulk water (0.045 ± 0.04 µmol.J -1 ) (Spinks,Woods, 1990). The H 2 radiolytic yield measured in the grafted sample is consistent, although higher, with measurements performed on other grafted SBA-15 samples (Zante et al, 2022). In this latter case, the major gas produced under irradiation was CO (and not H 2 ) due to the preferential radiolysis of the amide functional group.…”
Section: Gas Production Under Irradiationsupporting
confidence: 84%
“…Pristine SBA-15 has the highest specific surface (774 m².g -1 ). As expected, a decrease of the specific surface to 235 m².g -1 is observed after grafting of the organic compound (see Table 1) (Zante et al, 2022). This is assigned to the filling of the pores by grafting, as evidenced also by the decrease of the pore size (from 7.0 to 6.6 nm after grafting) and of the porous volume (from 1.17 to 0.49 cm 3 .g -1 after grafting).…”
Section: Characterization Of the Materials Before And After Graftingsupporting
confidence: 83%
See 1 more Smart Citation
“…And MDILs that were immobilized in the solid support. All of the samples exhibited a first stage of mass loss between 25 and 82 °C attributed to the moisture adsorbed by hygroscopic SBA-15 [ 57 ]. Pristine SBA-15 showed a more significant mass loss compared to the supports with immobilized DILs or MDILs.…”