Transfusion Medicine and Hemostasis 2009
DOI: 10.1016/b978-0-12-374432-6.00032-4
|View full text |Cite
|
Sign up to set email alerts
|

Granulocyte products

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
4
0

Year Published

2023
2023
2023
2023

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(4 citation statements)
references
References 3 publications
0
4
0
Order By: Relevance
“…21 The use of hetastarch in conjunction with Spectra Optia apheresis in our study was able to generate a product in which 96.5% of units contained ANC yields greater than the 4.0 Â 10 10 granulocyte per unit while 97.6% of units contained RBC volume less than 30 mL. 3,7 Collections typically take 2-3 h but may take longer depending on intake procedures, staffing levels, and alterations to the standard collection rate. 22 In this study, all collected products were able to be transfused within 24-h of collection with a median time of 7.0 h between the end of collection and start of transfusion.…”
Section: Discussionmentioning
confidence: 72%
See 3 more Smart Citations
“…21 The use of hetastarch in conjunction with Spectra Optia apheresis in our study was able to generate a product in which 96.5% of units contained ANC yields greater than the 4.0 Â 10 10 granulocyte per unit while 97.6% of units contained RBC volume less than 30 mL. 3,7 Collections typically take 2-3 h but may take longer depending on intake procedures, staffing levels, and alterations to the standard collection rate. 22 In this study, all collected products were able to be transfused within 24-h of collection with a median time of 7.0 h between the end of collection and start of transfusion.…”
Section: Discussionmentioning
confidence: 72%
“…The use of hetastarch to generate a better interface between the granulocyte and RBC components has been shown to improve granulocyte yield and minimize RBC contamination 21 . The use of hetastarch in conjunction with Spectra Optia apheresis in our study was able to generate a product in which 96.5% of units contained ANC yields greater than the 4.0 × 10 10 granulocyte per unit while 97.6% of units contained RBC volume less than 30 mL 3,7 . Collections typically take 2–3 h but may take longer depending on intake procedures, staffing levels, and alterations to the standard collection rate 22 .…”
Section: Discussionmentioning
confidence: 73%
See 2 more Smart Citations