Graphene oxide-modified polyaniline pigment for epoxy based anti-corrosion coatings

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
14
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 33 publications
(15 citation statements)
references
References 44 publications
1
14
0
Order By: Relevance
“…To further investigate the corrosion protection behavior of ER composites coating, RGO‐IL (RGO to IL with a weight ratio of 1 : 4) was selected to compare with other ER samples. Figure showed the Bode and Nyquist plots of the bare Q235, ER, IL/ER, RGO/ER, and RGO‐IL/ER coatings immersed in 3.5 wt % NaCl solution for 1 h. As shown in Figure A), for the bare Q235, there was a time constant in Nyquist plot, which of time constant should be associated to the passive film surface and steel surface respectively . The impedance modulus (Z′) approximated 123 Ω cm 2 .…”
Section: Resultsmentioning
confidence: 93%
See 1 more Smart Citation
“…To further investigate the corrosion protection behavior of ER composites coating, RGO‐IL (RGO to IL with a weight ratio of 1 : 4) was selected to compare with other ER samples. Figure showed the Bode and Nyquist plots of the bare Q235, ER, IL/ER, RGO/ER, and RGO‐IL/ER coatings immersed in 3.5 wt % NaCl solution for 1 h. As shown in Figure A), for the bare Q235, there was a time constant in Nyquist plot, which of time constant should be associated to the passive film surface and steel surface respectively . The impedance modulus (Z′) approximated 123 Ω cm 2 .…”
Section: Resultsmentioning
confidence: 93%
“…Figure 5 showed the Bode and Nyquist plots of the bare Q235, ER, IL/ER, RGO/ER, and RGO-IL/ER coatings immersed in 3.5 wt % NaCl solution for 1 h. As shown in Figure 5 A), for the bare Q235, there was a time constant in Nyquist plot, which of time constant should be associated to the passive film surface and steel surface respectively. [41] The impedance modulus (Z') approximated 123 W cm 2 . The Bode magnitude plots (Log j Z j vs Log (Freq/Hz)) of the samples after 1 h of immersion were displayed in Figure 5 B).…”
Section: The Eis Measurements For Various Coatingsmentioning
confidence: 99%
“…2 GO-based coatings and nanocomposite matrices, with high corrosion-prevention efficiency, even in saline waters, have also been developed. [5][6][7][8] In addition, several laboratory-scale studies have shown that GO is effective for water treatment. 9 The fate of GO has been extensively studied in synthetic media such as pure water with or without salts, [10][11][12] and less so in waters collected from natural freshwater sources including wastewater effluent, 11 rivers, 10,11 and lakes.…”
Section: Introductionmentioning
confidence: 99%
“…[8][9][10] A widely used method for preparing graphene/PANI is the use of graphene oxide (GO), combining GO with PANI using covalent bonds, which may cause damage to the conjugate structure of the GO sheets. Furthermore, GO was prepared via a modified Hummer's method, [11][12][13][14][15][16][17] which involves the use of strong oxidizing agent. Thus, it is of great importance to develop an environmentally friendly method to prepare graphene.…”
Section: Introductionmentioning
confidence: 99%